X4(
= Default name: a combination of the model name and the last three pairs of the interface MAC address
(for example: IPL-T-PC1-00-02-3D).
X5@
= Connection security level: 11 = user, 12 = administrator
= ASCII digits representing the numeric value of the data element read from the event buffer (leading zeros are
X5$
suppressed).
X5&
= IR file number: 0-99. The response is returned with leading zeros.
= IR function number: 0 = return all data, 1-127 = functions that can be played or can return information (text). The
X5*
response is returned with leading zeros., 129 = manufacturer, 130 = model, 131 = class, 132 = remote,
133 = creation date, 134 = comments, 137 = user file name (descriptive name given to the file by the user)
NOTE:
0 and numbers greater than 127 can return information only.
=
X5(
IR Playback mode: 0 = play once, 1 = play continuously
Response is returned with leading zeros.
To stop mode 1 playback, send the IR command again with mode 0 selected.
X6$
=
Time in seconds to keep sending the broadcast message (0-255, default = 10)
X6(
=
(Ethernet only) Number of seconds before timeout on IP connections (min. = 1, max. = 65000, and
default = 30 = 300 seconds).
If no data is received during the timeout period, the Ethernet connection is closed. Each step is 10 seconds. The
response is returned with leading zeros.
X7)
=
The number (as an optional parameter) that is inserted into the e-mail message if the .eml file has an embedded
command (with no parameters).
X7!
=
Hardware (MAC) address: the four most significant hex nibbles converted into a single 16-bit decimal number.
X7@
=
Hardware (MAC) address: the eight least significant hex nibbles converted into a single 32-bit decimal number.
This can be up to 10 digits.
NOTE:
X7#
=
E-mail account user name. Maximum length is 31 characters. This parameter is optional; commas cannot be used as
placeholders for it. If it is omitted from an issued command, any existing user account name is cleared.
X7$
=
E-mail account password. Maximum length is 31 characters. This parameter is optional; commas cannot be used as
placeholders for it. If it is omitted from an issued command, any existing user account password is cleared.
X71!
=
Days of the week: 1 = Sunday, 2 = Monday, 3 = Tuesday, 4 = Wednesday, 5 = Thursday, 6 = Friday, 7 = Saturday
X71@
=
Time in minutes (0-1440): 0 = 12 am (midnight), 1440 = clear schedule, Example: 1439 = 11:59
Use the following formula (in 24-hour time format): (hour x 60) + minutes = time in minutes
=
Power receptacle name (12 characters maximum)
X71#