3.
If the PC1 has never been configured and is still set for factory defaults, skip to step 4. If
not, perform a mode 4 system reset to restore the factory-set values (see
page 12).
CAUTION: The PC1 must be configured with the factory default IP address
(192.168.254.254) before you execute the ARP command, as described below.
4.
On the computer, access the command prompt as follows:
a.
From your Windows desktop
b.
On the Run window, enter
5.
At the command prompt enter
PC1, a space, and finally the PC1 MAC address (taken from the small label on the rear
Rear Panels
panel; see
For example:
arp -s 10.13.197.57 00-05-A6-01-33-0D
A space must separate
Figure 10.
ARP-S Command Screen
6.
Execute a ping command by entering
command prompt. For example:
ping 10.13.197.57
Ping is a utility or diagnostic tool that tests network connections. It is used to determine
if the host has an operating connection and is able to exchange information with
another host.
The response should be the new IP address of the PC1, as shown below.
menu, select
Start
. The command window opens.
cmd
, followed by the desired new IP address for the
arp -s
on page 5).
and the hyphen [
].
arp
-
, followed by the new IP address, at the
ping
IPL T PC1 • HTML Configuration and Control
Resetting
.
Run...
on
16