Extron electronics IP Link Series User Manual page 33

Power control interfaces
Table of Contents

Advertisement

IP Settings
The following settings are available in the
— The default is the product name followed by the last six digits of
Unit Name
the MAC address. You can give the unit a new name (such as
) consisting of up to 24 alphanumeric characters including the
BoardroomA-PC1
hyphen (
).
-
NOTE: The first character must be an alpha character, and the last character
cannot be a hyphen. The unit name is not case sensitive.
— DHCP is a communications protocol that assigns addresses on the local
DHCP
network automatically. Select the
NOTE: When DHCP is set to On, all other IP settings are disabled except Unit
Name.
— You can enter a new network address, a 32-bit number consisting of
IP Address
four sets of 8-bit numbers, separated by periods (
— A gateway is a device that connects your network with others
Gateway IP Address
that may be outside your local area network. You can enter your gateway address
(obtained from your network administrator), using the same format that is used for the
IP address. (If there is no gateway, this field defaults to
— The subnet mask is used to split IP networks into a series of
Subnet mask
subgroups (subnets). The mask is a binary pattern that is matched up with the IP
address to turn part of the host ID address field into a field for subnets. You can enter a
new subnet mask address using the same format that is used for the IP address.
To change the IP address settings:
1.
In the
section, make entries or selections in the available fields as desired.
IP Settings
2.
When finished making entries in this section, click
If you want to discard your entries without submitting them, click
previous values (do not click
Date and Time Settings
The following settings are available in the
NOTE: This section lets you set the date and time on your PC1 unit. However, the
passage of time is not reflected in the
page continues to display the settings you entered and does not increment them as
time passes. However, the PC1 itself continues to keep the correct time internally.
To display the current time on the screen:
1.
Click
on your web browser screen.
Refresh
— Select month, day, and year from the pull-down menus.
Date
— Select hours, minutes, and am or pm from the menus.
Time
— From the pull-down menu, select the time zone for the location of the PC1
Zone
(number of hours offset from Greenwich mean time).
Daylight Savings
observed in some countries. You can select one of the radio buttons to set the PC1
for daylight savings time for the U. S., Europe, or Brazil; or select
The following daylight savings periods are observed:
section:
IP Settings
or
radio button to enable or disable DHCP.
On
Off
nnn.nnn.nnn.nnn
Submit
).
Submit
Date/Time Settings
and
Date
Time
— Daylight savings time (DST) is a one-hour offset that is
IPL T PC1 • HTML Configuration and Control
or
LightsOn&Off
).
)
0.0.0.0.
to implement them.
to restore the
Cancel
section:
fields on the web page. The
to disable it.
Off
25