Comtech EF Data XPA-200 Installation And Operation Manual page 68

Solid-state high power amplifier
Table of Contents

Advertisement

XPA200-7984-I-OPT1, X-Band SSPA
hh = FET8 current in Hex, scaled 100mA per count
ii = FET9 current in Hex, scaled 100mA per count
jj = FET10 current in Hex, scaled 100mA per count
kk = FET11 current in Hex, scaled 100mA per count
ll = FET12 current in Hex, scaled 100mA per count
mm = FET13 current in Hex, scaled 100mA per count
nn = FET14 current in Hex, scaled 100mA per count
oo = FET15 current in Hex, scaled 100mA per count
pp = FET16 current in Hex, scaled 100mA per count
qq = FET17 current in Hex, scaled 100mA per count
rr = FET18 current in Hex, scaled 100mA per count
ss = FET19 current in Hex, scaled 100mA per count
5.8.3.11
Packed Utility Status
Packed Utility Status:
Confirmation:
where:
5.8.3.12
Packed Alarm Status
Packed Alarm Status:
Confirmation:
where:
XPA200-7984-I-OPT1, Rev.2
a = com1 mode; 0=RS-232, 1=RS-485-2, 2-RS-485-4
bb = Address in hex (01 to FF)
c = 0 if Baud Rate 9600
= 1 if Baud rate 4800
= 2 if Baud rate 2400
= 3 if Baud rate 1200
= 4 if Baud rate 300
d = 0 if Parity Even, 1 if Parity Odd
ee = LCD Contrast (0 to 30)
ff = LCD Brightness (0 to 30)
a = 1 if +28 Fault, else 0
b = 1 if +12 Fault, else 0
c = 1 if -12 Fault, else 0
d = 1 if +5 Fault, else 0
e = 1 if -5 Fault, else 0
f = 1 if +10 PS#1 Fault, else 0
g = 1 if +10 PS#2 Fault, else 0
h = 1 if TEMP Fault, else 0
i = 1 if FAN 1 Fault, else 0
j = 1 if FAN 2 Fault, else 0
k = 1 if PROC Fault, else 0
<DEV/PACRUS_'cr'
>DEV/PACRUS_abbcdeeff'cr''lf']
<DEV/PACRAS_'cr'
>DEV/PACRAS_abcdefghijk'cr''lf']
Remote Control
Remote Control
5-16