Comtech EF Data XPA-200 Installation And Operation Manual page 67

Solid-state high power amplifier
Table of Contents

Advertisement

XPA200-7984-I-OPT1, X-Band SSPA
5.8.3.8
Packed Configuration Status
Configuration Status: <DEV/PACRCS_'cr'
Confirmation:
where:
5.8.3.9
Packed Maintenance Status
Packed Maitenance Status: <DEV/PACRMS_'cr'
Confirmation:
where:
aa = +28 supply, 100mV per count above 10.0V in Hex
bb = +12 supply scaled 100mV per count in Hex
cc = -12 supply scaled 100mV per count in Hex
dd = +5 supply scaled 100mV per count in Hex
ee = -5 supply scaled -100mV per count in Hex
ff = +10 supply #1 scaled 100mV per count in Hex
gg = +10 supply #2 scaled 100mV per count in Hex
hhh = Signed temperature in degrees C (-10 to +95)
iii = RF forward pwr, .1 dBm steps above 32.0 dBm in
jjj = RF reverse pwr, .1 dBm steps above 25.0 dBm in
5.8.3.10
Packed FET Status
Packed FET Status:
Confirmation:
where:
aa = FET1 current in Hex, formula: FET1 = (aa * 3)mAmps
bb = FET2 current in Hex, scaled 100mA per count
cc = FET3 current in Hex, scaled 100mA per count
dd = FET4 current in Hex, scaled 100mA per count
ee = FET5 current in Hex, scaled 100mA per count
ff = FET6 current in Hex, scaled 100mA per count
gg = FET7 current in Hex, scaled 100mA per count
XPA200-7984-I-OPT1, Rev.2
>DEV/PACRCS_aabcdeefg'cr''lf']
aa = # of 0.25 dB steps in HEX above 0dB (0to120)
b = 1 if Amplifier ON, 0 if OFF
c = 1 if Tx ON, 0 if OFF
d = 1 if unit ONLINE, 0 if OFFLINE
ee = SSPA number = BU,01 or 02 (if e = 0, ff = 00)
f = A if Auto Mode, M if Manual Mode
g = 1 if Auto Recovery enabled, else 0
Hex
Hex
>DEV/PACRMS_
aabbccddeeffgghhhiiijjj'cr''lf']
<DEV/PACRFS_'cr'
>DEV/PACRFS_
aabbccddeeff. . rrss'cr''lf']
Remote Control
Remote Control
5-15

Advertisement

Table of Contents
loading

Table of Contents