Comtech EF Data XPA-200 Installation And Operation Manual page 66

Solid-state high power amplifier
Table of Contents

Advertisement

XPA200-7984-I-OPT1, X-Band SSPA
5.8.3.5
Alarm Status
Alarm Status:
Confirmation:
5.8.3.6
Summary Alarm Status
Summary alarm is set to Fault (FT) if any of the items in
paragraph 5.8.4.5 are faulted.
Summary Alarm:
Confirmation:
5.8.3.7
Terminal Status Change
The TSC_ command can be used to determine if the status of
the terminal has changed since it was last polled.
parameters listed in the RCS or RUS commands have changed as a
result of user operations or if any new fault condition occur the
TSC_ command will return YES.
continue to return YES until any of the following commands are
received: RCS_, RUS_, RAS_, PACRCS_, PACRUS_, or PACRAS.
Configuration Status:
Confirmation:
XPA200-7984-I-OPT1, Rev.2
<DEV/RAS_'cr'
>DEV/RAS_'cr'
+28_xx'cr'
+12_xx'cr'
-12_xx'cr'
+5_xx'cr'
-5_xx'cr'
+10_1_xx'cr'
+10_2_xx'cr'
TEMP_xx'cr'
FAN1_xx'cr'
FAN2_xx'cr''lf']
<DEV/SAS_'cr'
>DEV/SAS_xx'cr''lf']
The TSC_ command will then
<DEV/TSC_'cr'
>DEV/TSC_nnn'cr''lf']
Remote Control
Remote Control
+28 VDC Fault
+12 VDC Fault
-12 VDC Fault
+5 VDC Fault
-5 VDC Fault
+10 PS#1 Fault
+10 PS#2 Fault
Temperature Fault
Fan 1 Fault
Fan 2 Fault
xx = OK or FT
xx = OK or FT
If any of the
nnn = YES/NO
5-14