Comtech EF Data XPA-200 Installation And Operation Manual page 61

Solid-state high power amplifier
Table of Contents

Advertisement

XPA200-7984-I-OPT1, X-Band SSPA
5.8.1.5
Parity Bit
The default parity is even.
Set Parity Bit:
Confirmation:
Retrieve Parity Bit:
Confirmation:
5.8.1.6
LCD Contrast
The default is 15.
Set Contrast:
Confirmation:
Retrieve Contrast:
Confirmation:
5.8.1.7
LCD Brightness
The default is 15.
Set Brightness:
Confirmation:
Retrieve Brightness:
Confirmation:
5.8.1.8
Lamp Test
The default is off.
Test Lamps:
Confirmation:
Lamp Test Status:
Confirmation:
XPA200-7984-I-OPT1, Rev.2
<DEV/SPB_xxxx'cr'
>DEV/SPB_xxxx'cr''lf']
<DEV/SPB_'cr'
>DEV/SPB_xxxx'cr''lf']
<DEV/CON_xx'cr'
>DEV/CON_xx'cr''lf']
<DEV/CON_'cr'
>DEV/CON_xx'cr''lf']
<DEV/LCD_xx'cr'
>DEV/LCD_xx'cr''lf']
<DEV/LCD_'cr'
>DEV/LCD_xx'cr''lf']
<DEV/LAM_xxx'cr'
>DEV/LAM_xxx'cr''lf']
<DEV/LAM_'cr'
>DEV/LAM_xxx'cr''lf']
Remote Control
Remote Control
xxxx = ODD
or EVEN
xx = 0 to 30
xx = 0 to 30
xxx = ON or OFF
5-9