Brother BAS H Series Instruction Manual page 104

Hide thumbs Also See for BAS H Series:
Table of Contents

Advertisement

CHAPTER 4 EXTENDED OPTION OUTPUT (PROGRAM)
 Sequence output
This assumes that the option output is for the stacker (a device that ejects material after sewing is complete). It creates
an example of sequence output after the work clamp rises when sewing ends.
First, make the settings for option output No. 15 so that it turns on and off corresponding to the raising of the work
clamp. Next, set No. 16 so that it turns on and off, and then add the condition at the end of sewing as explained in the
section below.
1. Have the programmer at hand and display the output settings.
2. Referring to the table of condition numbers of the standard output (refer to page 85), set output condition No. 15 to
"ON when condition No. 30 is established (after the work clamp rises)". Set Timer 2 to 1.2 sec. (1200 ms).
Enter the following in the extended option output settings.
3. Referring to the table of condition numbers of the extended option output (refer to page 86), set the output condition
for No. 16 to "condition No. 98 (when No. 15 is turned on)". Set Timer 1 to 0.5 sec. (500 ms) and Timer 2 to 0.7 sec.
(700 ms).
On the setting screen, make the following settings.
4. Touch
to overwrite the extended option output.
5. Display the extended option output settings once more. Touch
overwritten in step 4 to the sewing machine.
6. Carry out sewing operation. Set the memory switch No. 50 to 3 (the work clamps are automatically raised when
sewing is completed) to carry out sewing operation. Confirm that the left work clamp (No. 15) is turned on and right
work clamp (No. 16) is turned on after a 0.5 sec. delay and both are turned off in 0.7 sec. corresponding with the
raising of the work clamps (in this example, the right and left work clamps operate as option outputs).
Depress the foot pedal to confirm that No. 15 and 16 are turned on and off. When restarting, confirm that the
intermittent clamp is at the lowered position.
In sequence output mode (outputs are continuously turned on and off), it can be useful to specify the first output that
turns on as the output condition for sewing machine operation. Then specify the moments when the first output turns
on or off as the output condition for subsequent outputs.