Electrical Connections; Process Sealing - ABB CoriolisMaster FCH400 Series Operating Instructions Manual

Coriolis mass flowmeter
Hide thumbs Also See for CoriolisMaster FCH400 Series:
Table of Contents

Advertisement

22
CoriolisMaster FCB400, FCH400 CORIOLIS MASS FLOWMETER | OI/FCB400/FCH400-EN REV. E
... 2 Use in potentially explosive atmospheres
... Installation instructions

Electrical connections

Note
The temperature at the cable entries of the device depends on
the design, the measuring medium temperature T
ambient temperature T
amb.
For the electric connection of the device, use only cables with
sufficient temperature resistance in accordance with the tables
at Temperature resistance for the connecting cable on page 12.
Grounding
The sensor must be grounded in accordance with the applicable
international standards.
Perform grounding of the device in accordance with Pin
assignment on page 48.
In accordance with NEC standards, an internal ground
connection is present in the device between the sensor and the
transmitter.
Perform grounding of the device in accordance with Pin
assignment on page 48.
medium
.

Process sealing

In accordance with 'North American Requirements for Process
Sealing between Electrical Systems and Flammable or
Combustible Process Fluids'.
and the
Note
The device is suitable for use in Canada.
For use in Class II, Groups E, F and G, a maximum surface
temperature of 165 °C (329 °F) may not be up-scaled.
All cable (conduits) should be sealed from the device within a
distance of 18 in (457 mm).
ABB flowmeters are designed for the worldwide industrial
market and are suitable for functions such as the measurement
of flammable and combustible liquids and can be installed in
process pipes.
Connecting devices with cable (conduits) to the electric
installation makes it possible for measuring media to reach the
electric system.
To prevent measuring media from seeping into the electric
installation, the devices are equipped with process gaskets
which meet requirements in accordance with ANSI / ISA 12.27.01.
Coriolis mass flowmeters are designed as 'Single Seal Devices'.
With the TE2 order option, 'Extended tower length - insulation
capacity with dual gasket', the devices can be used as a 'Dual
Seal Devices'.
In accordance with the requirements of standard
ANSI / ISA 12.27.01, the existing operating limits of temperature,
pressure and pressure bearing parts must be reduced to the
following limit values:
Limit values
Flange or pipe material
Nominal sizes
Operating temperature
Process pressure
No limitations
DN 15 to DN 150
(½ to 6 in)
-50 °C to 205 °C
(-58 °F to 400 °F)
PN 100 / Class 600