CI/FCM2000-EN
CoriolisMaster FCM2000
Commissioning Instruction
EN
Mass Flowmeter
CoriolisMaster FCM2000
English
®
P R O F I
PROCESS FIELD BUS
B U S

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CoriolisMaster FCM2000 and is the answer not in the manual?

Questions and answers

Summary of Contents for ABB CoriolisMaster FCM2000

  • Page 1 CI/FCM2000-EN CoriolisMaster FCM2000 Commissioning Instruction Mass Flowmeter CoriolisMaster FCM2000 English ® P R O F I PROCESS FIELD BUS B U S...
  • Page 3 Fax: +49 621 381 931-29031 automation.service@de.abb.com © Copyright 2017 by ABB Automation Products GmbH Subject to changes without notice This document is protected by copyright. It assists the user in safe and efficient operation of the device. The contents of this document, whether whole or in part, may not be copied or reproduced without prior approval by the copyright holder.
  • Page 4: Table Of Contents

    Data entry ..............................19     Entering data in short form ........................... 21     Appendix ................................22     Other applicable documents ........................22     Approvals and certifications ......................... 22     2 - EN CoriolisMaster FCM2000 CI/FCM2000-EN...
  • Page 5: Safety

    Ex safety information is an integral part of this manual. As a result, it is crucial that the installation guidelines and connection values it lists are also observed. The icon on the name plate indicates the following: CI/FCM2000-EN CoriolisMaster FCM2000 EN - 3...
  • Page 6: Intended Use

    Approval ABB Automation Products GmbH must be sought for any activities beyond this scope. Repairs performed by ABB-authorized specialist shops are excluded from this. Technical limit values The meter has been designed for use exclusively within the values stated on the name plate and within the technical limit values specified on the data sheets.
  • Page 7: Approved Media

    Prior to using corrosive and abrasive measurement media, the operator must check the level of resistance of all parts coming into contact with the wetted parts. ABB Automation Products GmbH will gladly support you in selecting the materials, but cannot accept any liability in doing The operators must strictly observe the applicable national regulations with regards to installation, function tests, repairs, and maintenance of electrical products.
  • Page 8: Safety Instructions For Electrical Installation

    Wear to the flange gasket or process connection gaskets (e.g., aseptic threaded pipe connections, Tri-Clamp, etc.) may enable a pressurized medium to escape. When using internal flat gaskets, these can become embrittled by CIP/SIP processes. 6 - EN CoriolisMaster FCM2000 CI/FCM2000-EN...
  • Page 9: Design And Function

    Type ME24/25 A, U ... MS26 B, E 2. Remote mount design (small nominal diameters) Transmitter − Standard/non-Ex − Ex Zone 2/21, 22 G00387 Flowmeter sensor − Ex Zone 1/21 Fig. 1: FCM2000 overview CI/FCM2000-EN CoriolisMaster FCM2000 EN - 7...
  • Page 10: Transport

    General information on transport Observe the following when transporting the device to the measurement site: • The center of gravity is off center. • Flanged units may not be lifted by the converter housing or terminal box. 8 - EN CoriolisMaster FCM2000 CI/FCM2000-EN...
  • Page 11: Installation

    87 / 88 Sensor 2 5 Gray 6 Violet 7 White 8 Black 9 Orange 10 Yellow 11 "PA" equipotential bonding. When connecting transmitter to flowmeter sensor MS26, transmitter also has to be connected to "PA". CI/FCM2000-EN CoriolisMaster FCM2000 EN - 9...
  • Page 12: Electrical Connections Between The Transmitter And The Peripherals

    An additional document with Ex safety instructions is available for measuring systems that are used in explosion hazardous areas (Applies to FM / CSA only). As a result, it is crucial that the specifications and data it lists are also observed. 10 - EN CoriolisMaster FCM2000 CI/FCM2000-EN...
  • Page 13: Ex Relevant Specifications

    Terminals 33/34 Pulse output Active or passive Terminals 51/52 Contact output Passive Terminals 41/42 Contact input Passive Terminals 81/82 All inputs and outputs are electrically isolated from each other and from the supply power. CI/FCM2000-EN CoriolisMaster FCM2000 EN - 11...
  • Page 14: Atex/Iecex Ex Approval

    (PE) and the equipotential bonding (PA) in the potentially explosive area. 4.2.1 ATEX/IECEx Ex approval EC type-examination certificate in accordance with ATEX and IECEx KEMA ATEX 08ATEX0150 X, KEMA 08 ATEX 0151X, or IECEx KEM 08.0034X 12 - EN CoriolisMaster FCM2000 CI/FCM2000-EN...
  • Page 15 When using the device in explosion hazardous areas, the additional temperature specifications in the section titled "Ex relevant specifications" on the data sheet or in the the separate Ex safety instructions (SM/FCM2000/FM/CSA) must be observed. CI/FCM2000-EN CoriolisMaster FCM2000 EN - 13...
  • Page 16: Commissioning

    If the flow direction indicated on the display is incorrect, it could mean that the signal lead connections have been accidentally reversed. • The locations and the sizes of the fuses can be found in the section titled "Replaceable parts list" in the operating instructions. 14 - EN CoriolisMaster FCM2000 CI/FCM2000-EN...
  • Page 17: Information For Safe Operation - Atex, Iecex

    If the signal outputs are to be connected to intrinsically safe circuits, it is recommended that the included light blue caps be used for the corresponding cable connectors. CI/FCM2000-EN CoriolisMaster FCM2000 EN - 15...
  • Page 18: Namur Contact

    Special information for use in Category 1: • The inside of the meter tube or nominal sizes ≥ DN 50 (2") may correspond to Category 1 (Zone 0). The corrosion resistance of the materials must be taken into account. 16 - EN CoriolisMaster FCM2000 CI/FCM2000-EN...
  • Page 19: Information On Changing The Installation

    Visual inspection, particularly of the electronic circuit boards • Visual inspection: no damage or explosion can be detected Zone 1: • Visual inspection: no damage to the threads Ex d, non- (cover, 1/2" NPT cable glands) intrinsically safe circuits CI/FCM2000-EN CoriolisMaster FCM2000 EN - 17...
  • Page 20 The ambient temperature limits must be observed. If direct sunlight cannot be avoided, appropriate sun protection equipment must be installed. For FNICO or FISCO installations, the number of devices must be limited as per the applicable standard. 18 - EN CoriolisMaster FCM2000 CI/FCM2000-EN...
  • Page 21: Parameterization

    Access the parameter to be changed and set the new, selected, or default parameter. The ENTER function is effective for approx. 10 s only. If a new value is not entered within 10 s, the transmitter display reverts to the old value. CI/FCM2000-EN CoriolisMaster FCM2000 EN - 19...
  • Page 22 There are two different methods of entering data: • Numeric entry • Entry from predefined table Important When entering data, the values are checked for plausibility and, if necessary, rejected with an appropriate message. 20 - EN CoriolisMaster FCM2000 CI/FCM2000-EN...
  • Page 23: Entering Data In Short Form

    254.50 kg/h Exit "QmMax" STEP or DATA "Progr. level" or nominal size Specialist ENTER "Progr. level" blocked Starting point for "Process information" C/CE → V 98.14 % (transmitter remains online) →V 12,000 m CI/FCM2000-EN CoriolisMaster FCM2000 EN - 21...
  • Page 24: Appendix

    ATEX Directive (marking in addition to CE marking) IEC standards Approvals for Canada and United States IMPORTANT (NOTE) All documentation, declarations of conformity and certificates are available in ABB's download area. www.abb.com/flow 22 - EN CoriolisMaster FCM2000 CI/FCM2000-EN...
  • Page 28 ABB has Sales & Customer Support The Company’s policy is one of continuous product improvement and the right is reserved to modify the expertise in over 100 countries worldwide. information contained herein without notice. www.abb.com/flow Printed in the Fed. Rep. of Germany (07.2017) ©...