CoriolisMaster FCB400, FCH400 CORIOLIS MASS FLOWMETER | OI/FCB400/FCH400-EN REV. E
Zone 2, 21 and Division 2 – Model: FCx4xx-A2, FCx4xx-F2
Outputs on basic device
Current / HART output 31 / U
, active
CO
Terminals 31 / U
CO
Current / HART output 31 / 32, passive
Terminals 31 / 32
Digital output 41 / 42, active*
Terminals 41 / 42 and V1 / V2*
Digital output 41 / 42, active**
Terminals 41 / 42 and U
/ 32**
CO
Digital output 41 / 42, passive
Terminals 41 / 42
Digital output 51 / 52, active*
Terminals 51 / 52 and V1 / V2*
Digital output 51 / 52, passive
Terminals 51 / 52
All outputs are electrically isolated from each other and from the power supply.
Digital outputs 41 / 42 and 51 / 52 are not electrically isolated from each other. Terminals 42 / 52 have the same potential.
*
Only in conjunction with additional '24 V DC loop power supply (blue)' plug-in card in slot OC1.
** Only in conjunction with current output U
page 50.
Inputs and outputs with optional plug-in cards
Current output V3 / V4, active*
Terminals V3 / V4 and V1 / V2*
Current output V1 / V2, passive**
Current output V3 / V4, passive**
Terminals V1 / V2** or V3 / V4**
Digital output V3 / V4, active*
Terminals V3 / V4 and V1 / V2*
Digital output V1 / V2, passive**
Digital output V3 / V4, passive**
Terminals V1 / V2** or V3 / V4**
Digital input V3 / V4, active*
Terminals V3 / V4 and V1 / V2
Digital input V1 / V2, passive*
Digital input V3 / V4, passive*
Terminals V1 / V2** or V3 / V4**
Modbus® / PROFIBUS DP®
Terminals V1 / V2
*
Only in conjunction with additional '24 V DC loop power supply (blue)' plug-in card in slot OC1.
** The terminal assignment depends on the model number or the slot assignments. For connection examples, see Connection examples on page 53.
/ 32 in 'Powermode', see Current output Uco / 32 as loop power supply for digital output 41 / 42 or 51 / 52 on
CO
Operating values (general)
U
I
N
N
30 V
30 mA
30 V
30 mA
30 V
30 mA
30 V
30 mA
30 V
25 mA
30 V
30 mA
30 V
30 mA
Operating values (general)
U
I
N
N
30 V
30 mA
30 V
30 mA
30 V
25 mA
30 V
30 mA
30 V
3.45 mA
30 V
3.45 mA
30 V
30 mA
17
Type of protection – 'nA' / 'NI'
U
I
N
N
30 V
30 mA
30 V
30 mA
30 V
30 mA
30 V
30 mA
30 V
25 mA
30 V
30 mA
30 V
30 mA
Type of protection – 'nA' / 'NI'
U
I
N
N
30 V
30 mA
30 V
30 mA
30 V
25 mA
30 V
30 mA
30 V
3.45 mA
30 V
3.45 mA
30 V
30 mA