CoriolisMaster FCB400, FCH400 CORIOLIS MASS FLOWMETER | OI/FCB400/FCH400-EN REV. E
... 9 Operation
... Parameter descriptions
Menu / parameter
Device Setup / ...Transmitter / ...Units
Unit Massflow Qm
Unit Mass Totalizer
Unit Volumeflow Qv
Unit Vol. Totalizer
Density
Unit Temperature
Concentration
Variable 1 Name
Variable 2 Name
Device Setup / ...Transmitter / ...Custom Units
Mass flow Qm Name
Mass flow Qm Factor
Mass Tot. Name
Mass Tot. Factor
Volumeflow Qv Name
Volumeflow Qv Factor
Volume Tot. Name
Volume Tot. Factor
Density Name
Density Factor
Temperature Name
Temperature Factor
Description
Selection of unit for mass flow.
Refer to Table 2: Units for mass flow on page 78.
The selection applies to the display of the current mass flow, and for the parameters related to mass flow such as QmMax
and QmMaxDN.
Selection of unit for the mass counters.
Refer to Table 6: Units for the mass totalizer on page 79.
Selection of unit for volume flow.
Refer to Table 7: Units for the volume totalizer on page 79.
The selection applies to the display of the current volume flow and for the parameters related to volume flow such as
QvMax and QvMaxDN.
Selection of unit for the volume totalizers.
Refer to Table 7: Units for the volume totalizer on page 79.
Selection of unit for the density.
Refer to Table 3: Density units on page 78.
Selection of unit for temperature.
Refer to Table 4: Temperature units on page 78.
Selection of unit for concentration measurement.
Refer to Table 5: Concentration units on page 79.
Selection of the unit for external process variables.
The transmitter can show two external process variables in the display. The process variables can be transferred from the
fieldbus master to the transmitter via the HART, Modbus or PROFIBUS DP protocol. You can configure the indicator through
the 'Display' menu.
Sets the name or abbreviation of the user-defined unit for mass flow.
Sets the factor of the user-defined unit for mass flow in kg / seconds.
Sets the name or abbreviation of the user-defined unit for the mass counter.
Sets the factor of the user-defined unit for the mass counter in kg.
Sets the name or abbreviation of the user-defined unit for volume flow.
Sets the factor of the user-defined unit for volume flow in liters/seconds.
Sets the name or abbreviation of the user-defined unit for the volume totalizer.
Sets the factor of the user-defined unit for the volume totalizer in liters.
Sets the name or abbreviation for the user-defined density unit.
Sets the factor for the user-defined density unit in liters/seconds.
Sets the name or abbreviation for the user-defined temperature unit.
Sets the factor for the user-defined temperature unit in °C.