Configuration and Use Manual
MMI-20048166
Service file
SMV: 20 Runs
Service Snapshot
Assert Log
4. Specify the folder on your PC where the log file will be saved.
14.3 SMV history and SMV log
The transmitter automatically saves test data for all SMV (Smart Meter Verification) tests. You can generate a
log containing data for the 20 most recent tests or for all SMV tests. The log is an ASCII file in .csv format.
Contents of SMV log
Each record in the SMV log represents an SMV test. Each record contains the following information:
•
Date and time of test
•
Data collected during the test
•
The abort code (15=test completed normally)
•
A pass/fail result for the left pickoff (0=Pass, 1=fail)
•
A pass/fail result for the right pickoff (0=Pass, 1=fail)
•
The sensor type code
•
The sensor serial number
SMV history and power-cycles
If the transmitter is rebooted or power-cycled, SMV history is not affected.
SMV history and configuration files
If you restore the factory configuration or upload a configuration file, SMV history is not affected.
SMV log
Device UID: 577937183
Device Tag: SUPPLY
Time Zone: GMT -7.00
Date Time
LPO Stiff
8/13/2018 19:27
0.285876
8/14/2018 7:27
-0.06137
8/14/2018 19:27
0.204754
8/15/2018 7:27
-0.15382
8/18/2018 16:27
0.251067
8/19/2018 19:27
-0.13654
Configuration and Use Manual
Description
Test data from the 20 most recent SMV tests.
An ASCII file containing a snapshot of the transmitter's
internal database. This file is used by customer service.
A troubleshooting file used by customer service.
RPO Stiff
LPO Mass
0.289738
0.155294
-0.05808
0.154748
0.20932
0.155185
-0.15216
0.154612
0.251782
0.155217
-0.14112
0.154602
Log files, history files, and service files
File name
SmvLast20Data.csv
service.dump
AssertLog.txt
RPO Mass
Damping
0.158114
4.41E-05
0.157556
4.02E-05
0.158004
4.35E-05
0.157416
3.93E-05
0.158031
4.34E-05
0.157396
3.89E-05
April 2019
Drv mA
...
1.301
...
1.304
...
1.308
...
1.307
...
1.308
...
1.287
...
149