Table 6-1: Interaction between actual flow direction and Sensor Flow Direction Arrow
Actual flow direction
4. Optional: Set User Name to the name you want to use for the inventory or totalizer.
User Name can have a maximum of 16 characters.
The transmitter automatically generates a name for each totalizer and inventory, based on its source,
direction, and type.
Example
Totalizer Source=Mass Flow
Totalizer Direction=Forward Only
Totalizer name= Mass Fwd Total
Example
Inventory Source=Gas Standard Volume Flow
Inventory Direction=Bidirectional
Inventory name= GSV Bidir Inv
The specified name is used on the transmitter display and on all interfaces that support it. If User Name
contains only spaces, the transmitter-generated name is used. Not all interfaces support totalizer and
inventory names.
Checking for backflow
You suspect that there is a significant amount of backflow through the sensor. To collect data, configure two
totalizers as follows:
Source=Mass Flow, Direction=Forward Only
Source=Mass Flow, Direction=Reverse Only
Reset both totalizers, allow them to run for an appropriate period, then look at the amount of reverse flow as
a percentage of forward flow.
Tracking three different process fluids
Three tanks are connected to a loading dock through a single meter. Each tank contains a different process
fluid. You want to track each process fluid separately.
1. Set up three totalizers, one for each tank.
2. Name the totalizers Tank 1 , Tank 2 , and Tank 3 .
3. Configure each totalizer as required for the corresponding process fluid.
4. Stop and reset all three totalizers to ensure that the beginning values are 0.
5. When loading from a tank, start the corresponding totalizer, and stop it when the load is finished.
Configuration and Use Manual
Configure advanced options for process measurement
Setting of Sensor Flow Direction
Arrow
Against Arrow
April 2019
(continued)
Flow direction sent to outputs
and totalizers
Forward