Environment - Epson LS-B Series Safety And Installation

Robot system
Hide thumbs Also See for LS-B Series:
Table of Contents

Advertisement

2.5.2 Environment

In order to optimize the robot system's performance for safety, the Controller must
be placed in an environment that satisfies the following conditions:
NOTE
Ambient temperature
Ambient relative humidity
First transient burst noise
Electrostatic noise
Base table
If the Controller must be used in an environment that does not fulfill the conditions
mentioned above, take adequate countermeasures. For example, the Controller
may be enclosed in a cabinet with adequate ventilation and cooling.
- Install indoors only.
- Place in a well-ventilated area.
- Keep away from direct sunlight and radiation heat.
- Keep away from dust, oily mist, oil, salinity, metal powder or other
contaminants.
- Keep away from water.
- Keep away from shocks or vibrations.
- Keep away from sources of electronic noise
- Keep away from strong electric or magnetic fields.
Safety and Installation (RC90-B / EPSON RC+ 7.0) Rev.4
- The Controller is not designed for clean-room specification. If it
must be installed in a clean room, be sure to install it in a proper
enclosure with adequate ventilation and cooling.
- Install Controller in a location that allows easy connection /
disconnection of cables.
Item
Condition
5 to 40 °C
(with minimal variation)
20% to 80% (with no condensation)
2 kV or less
(Power supply wire)
1 kV or les
(Signal wire)
4 kV or less
Use a base table that is at least 100 mm off the
floor. (Placing the Controller directly on the
floor could allow dust penetration leading to
malfunction.)
2. Installation
59

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ls6-bLs3-bRc90-bLs20-bLs10-b