LYNX Monitor
b) Technical Specifi cations
- Operating temperature -5ºC to +40ºC.
- Relative humidity: 5-95%, without condensation.
Consumption (with external 12 Vdc supply):
• Boot-Up Process (up to 3 seconds after power is switched on): 430mA.
• Idle: 225 mA.
• Call: 805 mA, (Fermax1 melody at maximum).
• Conversation (video + audio): 630 mA.
Monitor Capacity and Parameters, (default values in brackets [ ]):
- Maximum number of monitors per dwelling: 8.
- Maximum number of dwellings per block: 8,192.
- PIN codes:
• User. 1 code. [Not used] / [1234]. Used to access user settings or messages. This may be modifi ed.
• User alarm. 1 code. [0000]. Used to change the Alarm PIN. This may be modifi ed.
• Installer. 1 code. [4444]. Used to access installer confi guration parameters.
This may be modifi ed.
- Conversation channels: Maximum of 1 per apartment.
- Conversation time: 90 seconds.
- Call ring tones 22.
• 20 predefi ned ADPCM, .wav or .mp3 melodies.
• 2 may be downloaded by users from the web server (.wav or .mp3).
- Call ring tone maximum time 30 seconds.
- Image memory 128 (QVGA 640x480 resolution).
- Text messages: 128. 128 character length.
- Audio Notes: Maximum recording time 300 seconds.
- IP address: automatically calculated based on the apartment block number and extension.
Labels
- Tenant name: 16 characters
- Monitor label: 16 characters
- Maximum times:
• Switch-on: 30 seconds. The system will boot up to full functionality within 60 seconds.
• Video connection after call reception: 2 seconds.
• Video connection after auto switch-on: 2 seconds.
• Audio and video delay (from panel to monitor): 0.2 seconds.
• Audio / video desynchronisation: 0.05 seconds.
• Relay activation delay 0.5 seconds.
Issues to keep in mind before performing an FW update:
• Ensure that the new version of FW is compatible with all other devices on the installation.
• Update the remaining monitors / panels to the same FW version.
• If you return to a previous version of the FW, it is very likely that the parameters of the current device
confi guration will be lost. To avoid this, a backup must be made before upgrading.