■Cable clamp fitting AERSBAN-_SET
Generally, connecting the grounding wire of the shielded wire to the SD terminal of the connector provides a sufficient effect.
However, the effect can be increased when the shielded wire is connected directly to the ground plate as shown below.
Install the ground plate near the servo amplifier for the encoder cable. Peel part of the cable insulator to expose the external
conductor, and press that part against the ground plate with the cable clamp. If the cable is thin, clamp several cables in a
bunch.
The cable clamp comes as a set with the grounding plate.
[Unit: mm]
Clamp fittings
(A, B)
Clamp section diagram
• Dimensions
[Unit: mm]
Grounding plate
2-φ5 hole
17.5
Mounting hole
6
22
*1
M4 screw
35
*1 Screw hole for grounding. Connect it to the ground plate of the cabinet.
Model
AERSBAN-DSET
AERSBAN-ESET
Clamp fitting
A
B
Precautions
• The motor cable (single cable type) has no shield on the outermost circumference. Therefore, to ground the motor cable
with a cable clamp, use a motor cable (dual cable type).
6 OPTIONS AND PERIPHERAL EQUIPMENT
182
6.13 Noise reduction techniques
Strip the cable insulator
of the clamped area.
Cable
Grounding plate
External conductor
Clamp fitting
L or less
A
100
70
Cutter
Cable
10
B
C
86
30
56
L
70
45
Accessory fittings
Clamp A: 2pcs.
Clamp B: 1pc.