Ex approval

Sanitary compatibility

HART certification

Certification PROFIBUS

84
Заказывайте на сайте: www.tinnova.ru/endress_hauser/ || Эл. почта: info@tinnova.ru
The measuring device is certified for use in hazardous areas and the relevant safety instructions are
provided in the separate "Safety Instructions" (XA) document. Reference is made to this document on
the nameplate.
The separate Ex documentation (XA) containing all the relevant explosion protection data is
available from your Endress+Hauser sales center.
ATEX/IECEx
Currently, the following versions for use in hazardous areas are available:
Ex ia
Category (ATEX)
II2G
II1/2G, II2D
II2G, II2D
Ex nA
Category (ATEX)
II3G
CSA
C
US
Currently, the following versions for use in hazardous areas are available:
IS (Ex i)
• Class I Division 1 Groups ABCD
• Class II Division 1 Groups EFG and Class III
NI (Ex nA)
Class I Division 2 Groups ABCD
• 3-A approval
Only devices with the order code for "Additional approval", option LP "3A" have 3-A approval.
• EHEDG-tested
Only devices with the order code for "Additional approval", option LT "EHEDG" have been tested and
meet the requirements of the EHEDG.
To meet the requirements for EHEDG certification, the device must be used with process
connections in accordance with the EHEDG position paper entitled "Easy Cleanable Pipe Couplings
and Process Connections" (www.ehedg.org).
HART interface
The measuring device is certified and registered by the FieldComm Group. The measuring system
meets all the requirements of the following specifications:
• Certified according to HART 7
• The device can also be operated with certified devices of other manufacturers (interoperability)
PROFIBUS interface
The measuring device is certified and registered by the PNO (PROFIBUS User Organization
Organization). The measuring system meets all the requirements of the following specifications:
• Certified in accordance with PROFIBUS PA Profile 3.02
• The device can also be operated with certified devices of other manufacturers (interoperability)
Proline Promass E 100
Type of protection
Ex ia IIC T6...T1 Gb or Ex ia IIB T6...T1 Gb
Ex ia IIC T6...T1 Ga/Gb or Ex ia IIB T6...T1 Ga/Gb
Ex tb IIIC Txx °C Db
Ex ia IIC T6...T1 Gb or Ex ia IIB T6...T1 Gb
Ex tb IIIC Txx °C Db
Type of protection
Ex nA IIC T6...T1 Gc or Ex nA IIC T5-T1 Gc