Endress+Hauser Proline Promass E 100 Manual page 32

Coriolis flowmeter
Hide thumbs Also See for Proline Promass E 100:
Table of Contents

Advertisement

Supply voltage
32
Заказывайте на сайте: www.tinnova.ru/endress_hauser/ || Эл. почта: info@tinnova.ru
Device plug for signal transmission (device side), MODBUS RS485 (not intrinsically safe)
For use in the non-hazardous area and Zone 2/Div. 2.
Pin
2
1
2
3
1
3
5
4
4
5
A0016811
Coding
• Recommended plug: Binder, series 763, part no. 79 4449 20 05
• When using the device in a hazardous location, use a suitably certified plug.
EtherNet/IP
Device plug for signal transmission (device side)
Pin
2
1
2
3
1
3
4
4
Coding
A0016812
Recommended plug:
• Binder, series 763, part no. 99 3729 810 04
• Phoenix, part no. 1543223 SACC-M12MSD-4Q
• When using the device in a hazardous location, use a suitably certified plug.
PROFINET
Device plug for signal transmission (device side)
Pin
2
1
2
1
3
3
4
4
Coding
A0016812
Recommended plug:
• Binder, series 763, part no. 99 3729 810 04
• Phoenix, part no. 1543223 SACC-M12MSD-4Q
• When using the device in a hazardous location, use a suitably certified plug.
The power unit must be tested to ensure it meets safety requirements (e.g. PELV, SELV).
A
B
B
+
+
-
-
D
+
+
-
-
D
Proline Promass E 100
Assignment
Not assigned
Modbus RS485
Not assigned
Modbus RS485
Grounding/shielding
Plug/socket
Socket
Assignment
Tx
Rx
Tx
Rx
Plug/socket
Socket
Assignment
TD +
RD +
TD –
RD –
Plug/socket
Socket
Endress+Hauser

Hide quick links:

Advertisement

Table of Contents
loading