CE mark

C-Tick symbol

Ex approval

Functional Safety

Sanitary compatibility (in
preparation)

AD2000

Pressure Equipment Directive
(in preparation)
Steam boiler approval (in
preparation)

Telecommunications

CRN approval (in preparation)

Other standards and
guidelines
60

Certificates and approvals

The measuring system meets the legal requirements of the applicable EC guidelines. These are listed in the
corresponding EC Declaration of Conformity together with the standards applied.
Endress+Hauser confirms successful testing of the device by affixing to it the CE mark.
The measuring system meets the EMC requirements of the "Australian Communications and Media Authority
(ACMA)".
The devices are certified for use in hazardous areas and the relevant safety instructions are provided in the
separate "Safety Instructions" (XA) document. Reference is made to this document on the nameplate.
The separate documentation "Safety Instructions" (XA) containing all the relevant explosion protection
data is available from your Endress+Hauser Sales Center. Correlation of documentations to the device
(® ä 75).
Used for level monitoring (MIN, MAX, range) up to SIL 3 (homogeneous redundancy), independently assessed
by TÜV Rhineland as per IEC 61508. Other information see documentation SD00326F: "Functional Safety
Manual".
FMP52 with rod probe is available with sanitary process connections (Dairy coupling DIN 11851, Tri-Clamp).
The gap-free connections can be cleaned without residue using the usual cleaning methods.
Many versions of the Levelflex M meet the requirements of 3A-Sanitary Standard No. 74.
Endress+Hauser confirms this by attaching the 3A symbol.
The wetted material 316L (1.4435/1.4404) corresponds to AD2000 - W2/W10.
Conformity assessment was carried out as per Module A, the proof of statical stability as per EN 13445 and the
proof of endurance strength as per EN13445 and AD2000 - data sheet 52.
The FMP54 corresponds to the 97/23/EC Directive (Pressure Equipment Directive). It is a pressure
accessory with a volume < 0.1 l, corresponding to Category I.
The FMP54 is not suitable for use with unstable gases at nominal pressures above 200 bar (2 900 psi).
The FMP54 is approved as a limiting device for high water (HW) and low water (LW) for liquids in containers
which are subject to the requirements of EN12952-11 and EN12953-9 (certified by TÜV Nord). Ordering
information (® ä 67). Further information can be found in the safety instructions for steam boiler approval
(in preparation).
Complies with part 15 of the FCC rules for an unintentional radiator. All probes meet the requirements for a
Class A digital device.
In addition, all probes in metallic tanks as well as the coax probe meet the requirements for a Class B digital
device.
Some device versions have CRN approval. For a CRN-approved device, a CRN-approved process connection
has to be ordered with a CSA approval.
• EN 60529
Degrees of protection by housing (IP code)
• EN 61010-1
Protection Measures for Electrical Equipment for Measurement, Control, Regulation and Laboratory
Procedures.
• IEC/EN 61326
"Emission in accordance with Class A requirements". Electromagnetic compatibility (EMC requirements)
• NAMUR NE 21
Electromagnetic compatibility (EMC) of industrial process and laboratory control equipment.
• NAMUR NE 43
Standardization of the signal level for the breakdown information of digital transmitters with analog output
signal.