Power Consumption; Current Consumption; Power Supply Failure - Endress+Hauser Proline Promass E 100 Manual

Coriolis flowmeter
Hide thumbs Also See for Proline Promass E 100:
Table of Contents

Advertisement

Proline Promass E 100

Power consumption

Current consumption

Power supply failure

Endress+Hauser
Заказывайте на сайте: www.tinnova.ru/endress_hauser/ || Эл. почта: info@tinnova.ru
Transmitter
For device version with communication type:
• HART, PROFIBUS DP, EtherNet/IP: DC 20 to 30 V
• Modbus RS485, device version:
– For use in the non-hazardous area and Zone 2/Div. 2: DC 20 to 30 V
– For use in the intrinsically safe area: power supply via Safety Barrier Promass 100
Promass 100 safety barrier
DC 20 to 30 V
Transmitter
Order code for "Output"
Option B: 4-20 mA HART with pulse/frequency/switch output
Option L: PROFIBUS DP
Option M Modbus RS485, for use in non-hazardous areas and Zone 2/
Div. 2
Option M: Modbus RS485, for use in intrinsically safe areas
Option N: EtherNet/IP
Option R: PROFINET
Promass 100 safety barrier
Order code for "Output"
Option M: Modbus RS485, for use in intrinsically safe areas
Transmitter
Order code for "Output"
Option B: 4-20mA HART, pul./freq./switch output
Option L: PROFIBUS DP
Option M Modbus RS485, for use in non-hazardous
areas and Zone 2/Div. 2
Option M: Modbus RS485, for use in intrinsically safe
areas
Option N: EtherNet/IP
Option R: PROFINET
Promass 100 safety barrier
Order code for "Output"
Option M: Modbus RS485, for use in intrinsically safe
areas
• Totalizers stop at the last value measured.
• Depending on the device version, the configuration is retained in the device memory or in the
plug-in memory (HistoROM DAT).
• Configuration is retained in the plug-in memory (HistoROM DAT).
• Error messages (incl. total operated hours) are stored.
Maximum
Power consumption
3.5 W
3.5 W
3.5 W
2.45 W
3.5 W
3.5 W
Maximum
Power consumption
4.8 W
Maximum
Current consumption
switch-on current
145 mA
18 A (< 0.125 ms)
145 mA
18 A (< 0.125 ms)
90 mA
10 A (< 0.8 ms)
145 mA
16 A (< 0.4 ms)
145 mA
18 A (< 0.125 ms)
145 mA
18 A (< 0.125 ms)
Maximum
Current consumption
switch-on current
230 mA
10 A (< 0.8 ms)
Maximum
Maximum
33

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents