Endress+Hauser Proline Promass E 100 Manual page 64

Coriolis flowmeter
Hide thumbs Also See for Proline Promass E 100:
Table of Contents

Advertisement

64
Заказывайте на сайте: www.tinnova.ru/endress_hauser/ || Эл. почта: info@tinnova.ru
Threaded couplings
Thread DIN 11851, DIN11864-1, SMS 1145
Length tolerance for dimension L in mm:
+1.5 / –2.0
Thread DIN 11851, for pipe according to DIN11866, series A
1.4404 (316/316L)
Order code for "Process connection", option FMW
DN
[mm]
8
15
25
40
50
80
3-A version available: order code for "Additional approval", option LP in conjunction with
Ra ≤ 0.8 µm: Order code for "Measuring tube material", option SB
Ra ≤ 0.4 µm: Order code for "Measuring tube material", option SC
Thread DIN11864-1 Form A, for pipe according to DIN11866, series A
1.4404 (316/316L)
Order code for "Process connection", option FLW
DN
[mm]
8
15
25
40
50
80
3-A version available: order code for "Additional approval", option LP in conjunction with
Ra ≤ 0.8 µm: Order code for "Measuring tube material", option SB
Ra ≤ 0.4 µm: Order code for "Measuring tube material", option SC
A
[in]
Rd 34 × ¹⁄₈
Rd 34 × ¹⁄₈
Rd 52 × ¹⁄₆
Rd 65 × ¹⁄₆
Rd 78 × ¹⁄₆
Rd 110 × ¹⁄₄
A
[in]
Rd 28 × ¹⁄₈
Rd 34 × ¹⁄₈
Rd 52 × ¹⁄₆
Rd 65 × ¹⁄₆
Rd 78 × ¹⁄₆
Rd 110 × ¹⁄₄
Proline Promass E 100
L
B
L
[mm]
[mm]
16
229
16
273
26
324
38
456
50
562
81
671
B
L
[mm]
[mm]
10
229
16
273
26
324
38
456
50
562
81
671
Endress+Hauser
A0015628