Endress+Hauser Proline Promass E 100 Manual page 16

Coriolis flowmeter
Hide thumbs Also See for Proline Promass E 100:
Table of Contents

Advertisement

16
Заказывайте на сайте: www.tinnova.ru/endress_hauser/ || Эл. почта: info@tinnova.ru
Function codes
Broadcast messages
Supported baud rate
Data transfer mode
Data access
EtherNet/IP
Protocol
Communication type
Device profile
Manufacturer ID
Device type ID
Baud rates
Polarity
Supported CIP connections
Explicit connections
I/O connections
Configuration options for
measuring device
Configuration of the EtherNet
interface
Configuration of the device
address
Device Level Ring (DLR)
• 03: Read holding register
• 04: Read input register
• 06: Write single registers
• 08: Diagnostics
• 16: Write multiple registers
• 23: Read/write multiple registers
Supported by the following function codes:
• 06: Write single registers
• 16: Write multiple registers
• 23: Read/write multiple registers
• 1 200 BAUD
• 2 400 BAUD
• 4 800 BAUD
• 9 600 BAUD
• 19 200 BAUD
• 38 400 BAUD
• 57 600 BAUD
• 115 200 BAUD
• ASCII
• RTU
Each device parameter can be accessed via Modbus RS485.
For Modbus register information, see "Description of device parameters"
documentation
• The CIP Networks Library Volume 1: Common Industrial Protocol
• The CIP Networks Library Volume 2: EtherNet/IP Adaptation of CIP
• 10Base-T
• 100Base-TX
Generic device (product type: 0x2B)
0x49E
0x104A
Automatic ¹⁰⁄₁₀₀ Mbit with half-duplex and full-duplex detection
Auto-polarity for automatic correction of crossed TxD and RxD pairs
Max. 3 connections
Max. 6 connections
Max. 6 connections (scanner)
• DIP switches on the electronics module for IP addressing
• Manufacturer-specific software (FieldCare)
• Add-on Profile Level 3 for Rockwell Automation control systems
• Web browser
• Electronic Data Sheet (EDS) integrated in the measuring device
• Speed: 10 MBit, 100 MBit, auto (factory setting)
• Duplex: half-duplex, full-duplex, auto (factory setting)
• DIP switches on the electronics module for IP addressing (last octet)
• DHCP
• Manufacturer-specific software (FieldCare)
• Add-on Profile Level 3 for Rockwell Automation control systems
• Web browser
• EtherNet/IP tools, e.g. RSLinx (Rockwell Automation)
No
Proline Promass E 100
Endress+Hauser

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents