74
Заказывайте на сайте: www.tinnova.ru/endress_hauser/ || Эл. почта: info@tinnova.ru
Threaded couplings
Thread SMS 1145
Length tolerance for dimension L in inch:
+0.06 / –0.08
Thread SMS 1145
1.4404 (316/316L)
Order code for "Process connection", option SCS
DN
[in]
³⁄₈
¹⁄₂
1
2
3
3-A version available: order code for "Additional approval", option LP in conjunction with
Ra ≤ 32 µin: Order code for "Measuring tube material", option SB
Ra ≤ 16 µin: Order code for "Measuring tube material", option SC
A
[in]
Rd 40 × ¹⁄₆
Rd 40 × ¹⁄₆
Rd 40 × ¹⁄₆
Rd 60 × ¹⁄₆
Rd 70 × ¹⁄₆
Rd 98 × ¹⁄₆
Proline Promass E 100
L
B
L
[in]
[in]
0.89
9.02
0.89
10.75
0.89
12.76
1.40
17.95
1.91
22.13
2.87
26.42
Endress+Hauser
A0015628