Certificates And Approvals; Ce Mark; Ukca Marking; Rcm Marking - Endress+Hauser Proline Prosonic Flow P 500 Technical Information

Ultrasonic time-of-flight flowmeter
Hide thumbs Also See for Proline Prosonic Flow P 500:
Table of Contents

Advertisement

Proline Prosonic Flow P 500

CE mark

UKCA marking

RCM marking

Ex approval

Endress+Hauser
Data logging
Manual
If the Extended HistoROM application package (order option) is enabled:
• Recording of 1 to 4 channels of up to 1 000 measured values (up to 250 measured values per
channel)
• User configurable recording interval
• Export the measured value log via a variety of interfaces and operating tools e.g. FieldCare,
DeviceCare or web server

Certificates and approvals

Current certificates and approvals for the product are available at
product page:
1.
Select the product using the filters and search field.
2.
Open the product page.
3.
Select Downloads.
The device meets the legal requirements of the applicable EU Directives. These are listed in the
corresponding EU Declaration of Conformity along with the standards applied.
Endress+Hauser confirms successful testing of the device by affixing to it the CE mark.
The device meets the legal requirements of the applicable UK regulations (Statutory Instruments).
These are listed in the UKCA Declaration of Conformity along with the designated standards. By
selecting the order option for UKCA marking, Endress+Hauser confirms a successful evaluation and
testing of the device by affixing the UKCA mark.
Contact address Endress+Hauser UK:
Endress+Hauser Ltd.
Floats Road
Manchester M23 9NF
United Kingdom
www.uk.endress.com
The measuring system meets the EMC requirements of the "Australian Communications and Media
Authority (ACMA)".
The measuring device is certified for use in hazardous areas and the relevant safety instructions are
provided in the separate "Safety Instructions" (XA) document. Reference is made to this document on
the nameplate.
The separate Ex documentation (XA) containing all the relevant explosion protection data is
available from your Endress+Hauser sales center.
Proline 500
ATEX/IECEx
Currently, the following versions for use in hazardous areas are available:
Ex db ia
Transmitter
Category
Type of protection
II3G
Ex ec nC IIC T5...T4 Gc
Category
II2G
II2G
www.endress.com
on the relevant
Sensor
Type of protection
Ex db ia IIC T6...T1 Gb
Ex db ia IIC T6...T1 Gb