TABLE 3. Nozzle Control Valve Cable Connector Pins
Pin
1
Chassis Power (10.5 - 16.0 VDC)
2
CAN High (2.0 - 2.7 VDC)
3
Switch Out (2.5 - 3.2 VDC if NCV connected)
TROUBLESHOOTING 19-PIN BOOM CABLE CONNECTIONS
Boom connection cables alternate NCV power and ground circuits within the cable for banks of NCV's. Adjacent
NCV's may not necessarily not be on the same HC power and ground circuit. Look at the end of the plug to locate
the pin numbers.
TABLE 4. Boom Cable Connection Pins.
Pin
1
Black CAN GND
2
3
4
Green CAN LO (2.0 - 2.7 VDC)
5
Red CAN PWR (12.0 - 14.0 VDC)
6
Yellow CAN HI (2.0 - 2.7 VDC)
7
8
Red HC PWR 1 (10.5 - 16.0 VDC)
9
10
Black HC GND 1
TROUBLESHOOTING TERMINATOR CONNECTIONS
Terminator connection referenced from cable side.
TABLE 5. Terminator Connection Pins
Pin
A
B
Red CAN PWR (12.0 - 14.0 VDC)
C
TROUBLESHOOTING FLOW METER CABLES
Disconnect the extension cable from the flow meter. Hold the extension cable so that the keyway is facing toward
the 12 o'clock position.
Troubleshooting: Cable Troubleshooting
Description
Description
Description
Pin
Description
6
Chassis Ground (0 VDC)
Switch In (8.0 -13.0 VDC coming from PCII on
5
the first NCV's of the primary cable and 2.5 -
3.2 VDC from previous NCV on all others.)
4
CAN Low (2.0 - 2.7 VDC)
Pin
Description
11
12
Red HC PWR 2 (10.5 - 16.0 VDC)
13
14
Black HC GND 2
15
16
Red HC PWR 3 (10.5 -16.0 VDC)
17
Green FENCEROW SIG (10.5 - 16.0 VDC)
18
Black HC GND 3
Gray SW IN/ENABLE (8.0 - 13.0 VDC or 2.5 -
19
3.2 VDC)
Pin
Description
D
Black CAN GND
E
Yellow CAN HI (2.0 - 2.7 VDC)
F
Green CAN LO (2.0 - 2.7 VDC)
TROUBLESHOOTING
59