6. Select the Tip Size field and use the available options to select the orifice size of the tips currently installed on
the nozzle bodies.
•
NCV is the tip connected to the Hawkeye
nozzle.
•
If no tips are installed and liquid fertilizer is being applied, select NA as the tip size.
7. Select the Next button to proceed to the Nozzle Indexing prompt.
AUTOMATIC NOZZLE INDEXING
The automatic nozzle indexing process allows the Hawkeye
each nozzle control valve on the left and right boom circuits and may detect issues with system connection or
nozzle setup.
1. When prompted, select the Next button to begin the auto-indexing process.
®
2. Hawkeye
will begin indexing nozzle control valves from the center of the implement boom and move out to
the end of the left boom. The indexing process automatically repeats for the right boom circuit, starting from
the center and working towards the end of the boom. If an error is detected on either the left or right boom
®
circuits, the Hawkeye
operator to correct the error before continuing with the calibration wizard. If an error occurs, troubleshoot the
issue and press retry.
FENCE ROW SETUP
Fence row setup is only available if Sprayer was selected as the applicator type. If Applicator was selected, fence
row setup is skipped.
1. The Fence Row Setup prompt will display once the automatic indexing process completes.
2. Enable the fence row option if fence row valves are connected to the system. Select the Enable On Screen
Buttons box to control fence row valves through the on-screen interface. If using secondary input switches to
the boom sense for fence rows, enter the appropriate section input for the left and right fence rows.
3. Select the Next button to continue to the Section Setup prompt.
SECTION AND SWITCH SETUP
1. Select the Number of Sections field and enter the number of section on/off valves available for Hawkeye
section control.
NOTE:
Liquid fertilizer applicators running
section valves. In this case, enter the number of toolbar sections. For example, a toolbar that folds
twice on each side would have five sections (L outer, L inner, Center, R inner, R outer).
2. Select the Next button to display the Section Width Setup prompt.
3. Select the Section Width fields and enter the width of each section across the implement. In Applicator mode,
enter the number of Hawkeye
a.
Section 1 is always the farthest left section on the implement and the highest section number is always the
farthest right section.
b. Measure the width of the boom (or count the number of nozzles and multiply by the nozzle spacing)
controlled by each section and enter the section measurements to ensure that the system accurately
records section coverage during field applications.
c.
For liquid fertilizer applicators in Applicator mode, the Hawkeye
each treated as half a row. For example, an outer section consisting of four nozzle control valves with 30"
spacing would have a section width of 30" + 30" + 30" + 15" = 105".
4. Touch Next to display the Boom Offset page.
System Calibration: Initial Start Up and Calibration Wizard
Product Controller II ECU will halt the indexing process and prompt the machine
Hawkeye
®
NCV's in each toolbar section.
®
valve. The Bypass Tip is for secondary tips at each
®
system to automatically configure the location of
®
must have a single master valve instead of multiple
®
NCV's at each end of the toolbar are
SYSTEM CALIBRATION
®
15
Need help?
Do you have a question about the ISO Product Controller II and is the answer not in the manual?