POWER AND PRODUCT CONTROLLER II ECU HARNESS MAINTENANCE

1. Disconnect the Product Controller II ECU harness connector and inspect for signs of moisture or corrosion.
2. If moisture of corrosion is detected, use Deoxit D5, brushes, and compressed air to clean and dry the
connector.
3. When clean, apply a coating of Corrosion X HD to the connector mating surfaces and contacts.
4. Reattach the connectors.

BOOM HARNESS CONNECTOR MAINTENANCE

Prior to connecting the Hawkeye
following steps to all 6-pin NCV connectors and 19-pin circular connectors between the boom cables and Product
Controller II ECU cable connections to ensure high quality connections:
1. Verify the NCV connectors and the accompanying boom cable connectors are free of moisture, contamination,
or oxidation. Oxidation will appear as a dry, white coating on the contacts. If any connectors show signs of
moisture, contamination, or oxidation, perform Step 2 - Step 6. If this is a new installation, skip to Step 7. All
components listed below can be ordered in the Hawkeye
692).
2. Spray the connection with a deoxidizing agent (DeoxIT D5 is recommended (P/N 222-4001-006)).
: Power and Product Controller II ECU Harness Maintenance
C ABLE AND CONNECTOR
C H A P T E R E
MAINTENANCE
®
boom cable to the Hawkeye Nozzle Control Valves (NCV), perform the
®
NCV Connection Maintenance Kit (P/N 117-0171-