Appendix D Case Temperature Reference
Methodology
D.10
Objective and Scope
This appendix defines a reference procedure for attaching a thermocouple to the IHS of an
FC-LGA4 processor package for T
features of the FC-LGA4 package and of the LGA775 socket for which it is intended.
It describes the recommended equipment for the reference thermocouple installation, including
tools and adhesive part numbers.
D.11

Definitions

Definitions of common acronyms used in this appendix are given in the table below:
Table 8.
Definitions
Term
TTV
IPA
DMM
IHS
D.12

Supporting Test Equipment

To apply the reference thermocouple attach procedure, it is recommended to use the equipment (or
equivalent) given in the table below.
Table 9.
Supporting Test Equipment (Sheet 1 of 2)
Item
Microscope
DMM
Micromanipulator
(See Note below)
Loctite* 498 Adhesive
Adhesive Accelerator
Kapton* Tape
®
®
Intel
Celeron
D Processor in the 775-Land LGA Package Thermal Design Guide47
303730
Order #
measurement. This procedure takes into account the specific
C
Definition
Thermal Test Vehicle
Isopropyl Alcohol
Digital Multi Meter
Integrated Heat Spreader
Measurement and Output
Olympus* Light microscope or equivalent
Digital Multi Meter for resistance measurement
Test Fixture(s
Micromanipulator set from YOU* Ltd. or equivalent.
Mechanical 3D arm with needle (not included) to maintain TC
bead location during the attach process.
Miscellaneous Hardware
Super glue w/thermal characteristics
Loctite* 7452 for fast glue curing
For holding thermocouple in place

Case Temperature Reference Methodology

Description
)
Part Number
SZ-40
Not Available
YOU-3
49850
18490
Not Available