Form Factor; Thermal Solution Z-Height Constraints; Copper Heatsink - Intel Celeron D Thermal Design Manual

775-land lga package for embedded applications
Table of Contents

Advertisement

Figure 10. 1U Thermal Solution Z-Height Constraints
5.4
2U Form Factor
Intel has developed a reference thermal solution design for the Celeron D processor in the 775-land
LGA package for the 2U form factor. This design was optimized for the 2U form factor within the
available volume for the thermal solution. The motherboard component keep-outs can be seen in
Figure 37, "1U/2U Motherboard Component Keep-In Definition, Primary Side" on page 62
Figure 38, "1U/2U Motherboard Component Keep-In Definition, Secondary Side" on page
This solution requires 100% of the airflow to be ducted through the heatsink fins in order to
prevent heatsink bypass. It is a copper base and copper fin heatsink that is attached to the
motherboard with the use of a backplate. This solution is shown in
Figure 11. 2U Copper Heatsink
The performance of this thermal solution at multiple airflow rates is shown in
performance test data shown in the chart was collected to ensure that the thermal solution is
performing within expectations. This data implies no statistical significance. The final intended
thermal solution including, heatsink, airflow source, TIM, and attach mechanism must be validated
by system integrators. This heatsink solution uses the Shin-Etsu* G751 as the TIM.
®
®
Intel
Celeron
D Processor in the 775-Land LGA Package Thermal Design Guide33
303730
Order #
Intel Enabled Thermal Solutions
Figure
11.
Figure
12. The
and
63.