Board Deflection Definition; Board Deflection Configuration Definitions - Intel Celeron D Thermal Design Manual

775-land lga package for embedded applications
Table of Contents

Advertisement

LGA775 Socket Heatsink Loading
This board deflection metric provides guidance for mechanical designs that differ from the
reference design for ATX/µATX form factor.
A.2.2
Board Deflection Metric Definition
Board deflection is measured along either diagonal (refer to
d = dmax – (d1 + d2)/2
d' = dmax – (d'1 + d'2)/2
Configurations in which the deflection is measured are defined in
To measure board deflection, follow industry-standard procedures such as IPC for board deflection
measurement. Height gauges and possibly dial gauges may also be used.
Table 6.

Board Deflection Configuration Definitions

Configuration
Parameter
d_ref
d_BOL
d_EOL
Figure 14. Board Deflection Definition
Intel
38
Processor + Socket
load plate
Yes
Yes
Yes
d1
d'2
®
®
Celeron
D Processor in the 775-Land LGA Package Thermal Design Guide
Figure
14):
Table
Heatsink
No
Beginning of Life (BOL) deflection, no preload
Yes
BOL deflection with preload
Yes
End of Life (EOL) deflection
d'1
d2