Sil3 emergency shutdown device & pst controller
Table of Contents

Advertisement

Housing and Cover
Weight
Relay and Manifold
I/P Motor
Mounting Bracket
Magnet Holder
Pole Ring
Levers
®
HART
Information
DD Registered with HART
Communication Foundation
Yokogawa PRM
Diagnostics
DD for Handheld
HART CMD #3
76 | =BHGE
Table 14: Construction Material Specifications
Aluminum ASTM B85 Alloy SG100A standard
Stainless Steel optional (316L) Note: SST version is also SIL3
Standard - 7.4 lbs./ 3.357 kg
Stainless Steel - 16 lbs/ 7.257 kg
Single Acting - PPS, 300 Series Stainless Steel, nitrile 
diaphragms
430 stainless steel, PPS, 300 series stainless steel
300 series stainless steel
Corrosion Protected Anodized Aluminum 6061 T6
416 stainless steel
300 Series stainless steel
Table 15: System Connectivity
®
HART
®
Yes, from HART
www.hartcomm.org
ValVue ESD Plug-In application available
Valve signature, partial stroke test signature, emergency
shutdown signature, stroking speed, friction high, friction
low, valve breakout pressure, spring range, air supply
droop, filling and exhaust rate. Integration of alarms with
host using HART
Yes
®
HART
PV = Valve Position, 0-100%
SV = Actuator Pressure (P1-P2)
TV = Supply Pressure
QV = P2 for double acting units (not applicable)
rev 5, ManufacturerID 0065, DeviceID 00CB
®
Communication Foundation at
®
Command #48.
4-20 mA input signal
© 2018 Baker Hughes, a GE company, LLC. All rights reserved.