  • Page 1 Mooney ™ 22/22H Series Pilots Instruction Manual (Rev.A) Baker Hughes Data Classification: Public...
  • Page 2 REFERENCE INFORMATION IN ADDITION TO THE CUSTOMER/OPERATOR’S NORMAL OPERATION AND MAINTENANCE PROCEDURES. SINCE OPERATION AND MAINTENANCE PHILOSOPHIES VARY, BAKER HUGHES (AND ITS SUBSIDIARIES AND AFFILIATES) DOES NOT ATTEMPT TO DICTATE SPECIFIC PROCEDURES, BUT TO PROVIDE BASIC LIMITATIONS AND REQUIREMENTS CREATED BY THE TYPE OF EQUIPMENT PROVIDED.
  • Page 3: Table Of Contents

    Series 22 Pilot - Loading Type Valve Installation ................. 9 Maintenance ......................10 Pilot Assembly - Series 22 ........................10 Pilot Assembly - Series 22Н ......................... 13 Type 27 Restrictor Assembly........................ 14 Copyright 2022 Baker Hughes Company. All rights reserved. Mooney 22/22H Pilots Instruction Manual | 3...
  • Page 4: Product Description

    FlowMax HP actuator in gas applications. spring range of the black and white/green springs. OPEN Figure 1 - Series 22/22H Schematic 4 | Baker Hughes Copyright 2022 Baker Hughes Company. All rights reserved.
  • Page 5: General Description

    Series 22Н. It reduces the pilot diaphragm area and increases the spring range of the black and white/green springs. Figure 2 - Series 22/22H Diagram Copyright 2022 Baker Hughes Company. All rights reserved. Mooney 22/22H Pilots Instruction Manual | 5...
  • Page 6 200 - 450 psig (14 - 31 barg) White/Green 040-020-01 200 - 520 psig (14 - 36 barg) Black 040-009-01 400 - 900 psig (27 - 62 barg) White/Green 040-020-01 6 | Baker Hughes Copyright 2022 Baker Hughes Company. All rights reserved.
  • Page 7: Pilot Markings (Figure 3)

    Each spring is color coded to indicate Purple, Black and the control pressure range White/Green Figure 6 - Spring Range Nameplate for Series 22H Pilots Copyright 2022 Baker Hughes Company. All rights reserved. Mooney 22/22H Pilots Instruction Manual | 7...
  • Page 8: Series 22 Pilot - Piping Schematics - Loading Type Valves

    4. Sense line connecting the SENSE Port on the Series 22 pilot to the sense port on the FlowMax НР actuator. 5. Sense line connecting the FlowMax HP regulator to the downstream piping. 8 | Baker Hughes Copyright 2022 Baker Hughes Company. All rights reserved.
  • Page 9: Series 22 Pilot - Loading Type Valve Installation

    NOTE: The Actuator LOADING and SENSE lines are typically installed at the factory on new valves. Copyright 2022 Baker Hughes Company. All rights reserved. Mooney 22/22H Pilots Instruction Manual | 9...
  • Page 10: Maintenance

    Figure 8 - A paper clip, or pick easily extracts the O-Ring out of the pilot body. Diaphragm Diaphragm Retainer Figure 10 - Diaphragm Assembly for the 22 Series Pilot. 10 | Baker Hughes Copyright 2022 Baker Hughes Company. All rights reserved.
  • Page 11 8 ft-lbs (10.8 Nm) torque. Install Spring and Spring Follower. Lubricate Spring Follower with a Petroleum Grease such as Lubriplate™ No. 105. Copyright 2022 Baker Hughes Company. All rights reserved. Mooney 22/22H Pilots Instruction Manual | 11...
  • Page 12 Bottom Cap. NOTE: Over tightening an O-Ring joint will not improve the seal. Screw in until metal parts make contact and snug slightly. 12. Pilot assembly is now complete. 12 | Baker Hughes Copyright 2022 Baker Hughes Company. All rights reserved.
  • Page 13: Pilot Assembly - Series 22Н

    O-Ring facing up. White/Green Springs. 6. Follow assembly directions for Series 22 Pilot for steps 6В through 10. Figure 21 - Diaphragm Assembly Copyright 2022 Baker Hughes Company. All rights reserved. Mooney 22/22H Pilots Instruction Manual | 13...
  • Page 14: Type 27 Restrictor Assembly

    (Sense Connection) on the FlowMax НР. The Loading port is connected to the Lower Actuator housing connection on the FlowMax НР. Other control options are available. Please contact your Mooney Representative for additional information. 14 | Baker Hughes Copyright 2022 Baker Hughes Company. All rights reserved.
  • Page 15 Notes: Copyright 2022 Baker Hughes Company. All rights reserved. Mooney 22/22H Pilots Instruction Manual | 15...
  • Page 16 Copyright 2022 Baker Hughes Company. All rights reserved. Baker Hughes provides this information on an “as is” basis for general information purposes. Baker Hughes does not make any representation as to the accuracy or completeness of the information and makes no warranties of any kind, specific, implied or oral, to the fullest extent permissible by law, including those of merchantability and fitness for a particular purpose or use.