Baker Hughes Masoneilan SVI II ESD Quick Start Manual page 68

Sil3 emergency shutdown device & pst controller
Table of Contents

Advertisement

NOTE
Proceed with the following steps:
1. Press NEXT.
2. Field device has more status available.
3. Press NEXT.
4. Ignore next 50 occurrences of status?.
5. Press YES.
6. Change to MANual mode.
7. Scroll to line 6 "EXAMINE", press
8. Scroll down to line 5 read status.
9. Read message.
10. Press OK.
11. Repeat OK to read all messages until the display returns to read status.
12. Scroll down to line 6 clear status, press
13. If clear fault codes not completed appears, press OK and read the message
(Position Error, for example) or go to the troubleshooting guide.
14. Correct the problem (Is the air supply on?), and then go to clear status until Clear
Fault codes Completed appears.
15. Press OK.
68 | =BHGE
Process applied to the non-primary variable is outside the
operating limits of the field device.
->.
© 2018 Baker Hughes, a GE company, LLC. All rights reserved.
->.