A. Specifications and
References

Physical and Operational Specifications

This section provides the physical and operational specifications for the SVI II ESD. 
Specifications are subject to change without notice.
Operating Temperature Limits
Storage Temperature Limits
Temperature Effect
Supply Pressure Effect
Relative Humidity
Humidity Effect
Insulation Resistance
MTBF
Electromagnetic Compatibility
Electrostatic
Fast Transient Burst
Vibration Influence
Measured at SVI II ESD Housing
Magnetic Field Influence
© 2018 Baker Hughes, a GE company, LLC. All rights reserved.
Table 10: Environmental Specifications
-40° F to 185° F (-40° C to 85° C)
-58° F to 200° F (-50° C to 93° C)
< 0.005% / °F typical; -40° F to 180° F (< 0.01% / °C
typical; -40° C to 82° C)
0.05% per psi (.73% per bar)
10 to 90% non-condensing
Less than 0.2% after 2 days at 104° F (40° C), 95% Rel-
ative Humidity.
Greater than 10 G Ohms at 50% RH.
49 years based on MIL handbook calculation for elec-
tronic parts and field data on mechanical parts
Electrostatic discharge — No effect with contact dis-
charge level of 4KV and air discharge level of 8 KV
(IEC 1000-4-2)
Radio frequency interference — Less than 0.2% at 10
volts per meter (EN 50140)
No effect at 2 KV (Coupling clamp IEC 1000-4-4).
4 mm at 5 - 15 Hz - Negligible
2 G at 15 - 150 Hz Less than 2% of span
1 G at 150 - 2000 Hz - Less than 2% of span
Negligible at 30 A/m (EN61000-4-8)
CE MARK certified to EN50081-2 and EN50082-2