Summary of Contents for Baker Hughes Masoneilan 536V

  • Page 1 Masoneilan ™ 536V Back Pressure Microflow Regulators Instruction Manual Baker Hughes Data Classification : Public...
  • Page 2 OPERATOR ARE STRICTLY LIMITED TO THOSE EXPRESSLY PROVIDED IN THE CONTRACT RELATING TO THE SUPPLY OF THE EQUIPMENT. NO ADDITIONAL REPRESENTATIONS OR WARRANTIES BY BAKER HUGHES REGARDING THE EQUIPMENT OR ITS USE ARE GIVEN OR IMPLIED BY THE ISSUE OF THESE INSTRUCTIONS.
  • Page 3: Table Of Contents

    Part Replacement in Body S/A ����������������������������������������������������������������������������������������������������4 Packing box���������������������������������������������������������������������������������������������������������������������������������6 Replacing Diaphragm������������������������������������������������������������������������������������������������������������������8 Replacing O-ring (38) ������������������������������������������������������������������������������������������������������������������8 Maintenance of the actuator packing box ���������������������������������������������������������������������������������11 Parts Reference ..........................11 Masoneilan 536V Back Pressure Microflow Regulators Instruction Manual | c Copyright 2021 Baker Hughes Company. All rights reserved.
  • Page 4: Safety Warning

    Warranty When used without the safety alert symbol, indicates a Items sold by Baker Hughes are warranted to be free from defects potentially hazardous situation which, if not avoided, could in materials and workmanship for a period of one year from the result in property damage.
  • Page 5: Description-Operation

    (3e) and the same spacer (3f) are used in the four cases. See figure 2 to select the plug and seat ring combination to obtain the required Cv. Masoneilan 536V Back Pressure Microflow Regulators Instruction Manual | 2 Copyright 2021 Baker Hughes Company. All rights reserved. Plug and...
  • Page 6 0.04 0.10 0.25 Orifice Dia. 2mm Orifice Orifice Orifice Orifice 14,3 Dia. 1,6mm Dia. 4,5mm Dia. 9,5mm Dia. Figure 2 - Ten plug and seat ring assemblies (trim) 3 | Baker Hughes Copyright 2021 Baker Hughes Company. All rights reserved.
  • Page 7: Set Point Adjustment

    3.8 does not feature any seat ring gasket (2). flange (10) up the plug stem and remove the two nuts (8a) as well as the two mounting screws (16). Masoneilan 536V Back Pressure Microflow Regulators Instruction Manual | 4 Copyright 2021 Baker Hughes Company. All rights reserved.
  • Page 8 Figure 3 - Cross Section of Type 536 V Regulator. Range 0,5-3 psi See Parts References page 10 5 | Baker Hughes Copyright 2021 Baker Hughes Company. All rights reserved.
  • Page 9: Packing Box

    (101). rings of packing around the stem. Position the skive cut of each packing ring 120˚ from that of the adjacent ring. Masoneilan 536V Back Pressure Microflow Regulators Instruction Manual | 6 Copyright 2021 Baker Hughes Company. All rights reserved.
  • Page 10 Figure 5 - Cross Section of Type 536 V Regulator. Range 2-5 psi See Parts References page 10 7 | Baker Hughes Copyright 2021 Baker Hughes Company. All rights reserved.
  • Page 11: Replacing Diaphragm

    Adjustment”. Place back in service. 2-5 psi, remove also the diaphragm plate (40). g. Remove the diaphragm (39). Clean thoroughly all parts in preparation for reassembly. Masoneilan 536V Back Pressure Microflow Regulators Instruction Manual | 8 Copyright 2021 Baker Hughes Company. All rights reserved.
  • Page 12 Figure 6 - Cross Section of Type 536 V Regulator. Range 3-15 psi See Parts References page 10 9 | Baker Hughes Copyright 2021 Baker Hughes Company. All rights reserved.
  • Page 13 Figure 7 - Cross Section of Type 536 V Regulator. Range 10-40 ; 30-85 & 60-170 psi See Parts References page 10 Masoneilan 536V Back Pressure Microflow Regulators Instruction Manual | 10 Copyright 2021 Baker Hughes Company. All rights reserved.
  • Page 14: Maintenance Of The Actuator Packing Box

     Only on range 10-40 ; 30-85 and 60-170 psi  Only on range 0,5-3 psi  Only on range 0,5-3 and 2-5 psi  Only on range 3-15 ; 10-40 ; 30-85 and 60-170 psi 11 | Baker Hughes Copyright 2021 Baker Hughes Company. All rights reserved.
  • Page 15 Notes Masoneilan 536V Back Pressure Microflow Regulators Instruction Manual | 12 Copyright 2021 Baker Hughes Company. All rights reserved.
  • Page 16 Copyright 2021 Baker Hughes Company. All rights reserved. Baker Hughes provides this information on an “as is” basis for general information purposes. Baker Hughes does not make any representation as to the accuracy or completeness of the information and makes no warranties of any kind, specific, implied or oral, to the fullest extent permissible by law, including those of merchantability and fitness for a particular purpose or use.

Table of Contents