Connecting The Wiring To Terminal Strip Tb1 - Kodak RP X-OMAT M6B Installation Instructions Manual

Hide thumbs Also See for RP X-OMAT M6B:
Table of Contents

Advertisement

Connecting the Wiring to Terminal Strip TB1

[1]
Remove the LOWER ACCESS PANEL from the FEED-END of the processor.
[2]
Open the TRANSFORMER BOX DOOR.
[3]
Determine the supply voltage being applied to the processor.
[4]
Connect the main input power wires to TERMINAL STRIP TB1.
[5]
Take the appropriate ELECTRIC SERVICE LABEL from the PREPACK CARTON. Install the ELECTRIC
SERVICE LABEL on the DATA PLATE which is located on the REPLENISHER CHECK TUBE
BRACKET.
[6]
Connect the JUMPERS from the PREPACK CARTON to TERMINAL STRIP TB2. See the figure.
[7]
Dress the JUMPER wires neatly to prevent damage to the wires due to pinching or scraping by the panel
edge.
[8]
Close the TRANSFORMER BOX DOOR.
TRANSFORMER
BOX DOOR
Figure 29 Accessing Terminal Strip TB1 and Installing the Electric Service Label
28
TERMINAL
STRIP TB1
TERMINAL
STRIP TB2
H048_0083DCC
H048_0083DA
246626