Component Slot Allocation

Topics:

RMX 4000 Slot Numbering

Slot numbers are located on both the front and rear of the RMX 4000.
RMX 4000 Slot Numbering
RMX 4000 Slot Numbering
The components have been assigned dedicated slots as defined in the following table:
Slot ID/No.
1-4
5
6
7
8
9-11
12
Polycom, Inc.
Card/Component
MPMRx Cards
Fabric Switch Module (FSM 4000)
CPU 2
Logo Panel
CTNL 4000 unit (CPU 1)
AC Power Supply
Fan Drawer
Requirement
Mandatory: At least one MPMRx
card is required. Each media card
also requires either an RTM ISDN
or an RTM LAN card.
Mandatory
Not Available (NA)
Not Available (NA)
Mandatory
An RMX with AC power has three
power supplies installed. A 3rd
power supply is redundant (n+1).
Note:
Not used with
DC powered
systems. DC
powered
systems receive
Direct Current
from the DC
PEM.
Mandatory