Polycom RealPresence RMX 4000 Hardware Manual page 37

Collaboration server
Hide thumbs Also See for RealPresence RMX 4000:
Table of Contents

Advertisement

Connect Cables to the 12 PRI Ports, 1 LAN Port RTM ISDN Card
To connect cables to the 12 PRI ports, 1 LAN port RTM ISDN card:
Procedure
Connect the E1/T1 cables to PRI.
Connect the LAN cable to LAN 1 ports.
When LAN redundancy is enabled, LAN 1 is used for both management, media and signaling
network connection. Connect the media and signaling cable to LAN 2 port. By default this port is
used for signaling, but when LAN redundancy is enabled, LAN 2 is the backup of LAN 1 port.
Connect Cables to the 9 PRI Ports, 4 LAN Ports RTM ISDN Card
To connect cables to the 9 PRI ports, 4 LAN ports RTM ISDN card:
Procedure
1. Connect the E1/T1 cables to PRI.
2. In MPMRx card mode, connect the LAN cable to LAN1 and LAN 2.
RealPresence Collaboration Server (RMX) 4000 rear panel with AC powers and communication cables
Polycom, Inc.
RMX 4000 Installation
30