Install the Telescopic Rail Runners on the Rack

Rack Rail Runners require a minimum of 48 cm and a maximum of 80cm within the rack for installation.
Procedure
To install the Telescopic rail runners on the rack:
1. Determine the location of the Collaboration Server on the rack:
Allow for a 1U gap above and below the system for ventilation.
Use the Rack Spacer (item no. 3) to predetermine its position on the rack post, making sure
that square studs of the spacer fit into the rack post's square/rounded mounting holes. Mark
the spacer's location on the rack post. Repeat this process for the 3 remaining vertical posts
ensuring that the system can be horizontally seated.
Front view of RealPresence Collaboration Server (RMX) 2000/4000 rail runner assembly
2. Position the Rack Spacer (3) onto the marked rack post together with left rack rail runner
(item no. 1 which is labeled LEFT) and fasten the flat head screws 3*10 mm (4) as shown in the
following figure.