Install the Telescopic Rail Runners on the Rack
Rack Rail Runners require a minimum of 48 cm and a maximum of 80cm within the rack for installation.
Procedure
To install the Telescopic rail runners on the rack:
1. Determine the location of the Collaboration Server on the rack:
•
Allow for a 1U gap above and below the system for ventilation.
•
Use the Rack Spacer (item no. 3) to predetermine its position on the rack post, making sure
that square studs of the spacer fit into the rack post's square/rounded mounting holes. Mark
the spacer's location on the rack post. Repeat this process for the 3 remaining vertical posts
ensuring that the system can be horizontally seated.