ACV 01.2/ACVExC 01.2
16.2.

Selection overview of binary signals for digital inputs (DIN)

Table 23:
Signal
Not used
MODE
OPEN
CLOSE
STOP
RESET
I/O interface
OPEN / CLOSE
EMERGENCY
Intermediate pos. 1
Intermediate pos. 2
Intermediate pos. 3
Intermediate pos. 4
Intermediate pos. 5
Intermediate pos. 6
Intermediate pos. 7
Intermediate pos. 8
Input DIN 1
Input DIN 2
Input DIN 3
Input DIN 4
Enable Local
Enable OPEN
Enable CLOSE
PID internal setpoint 2
Remote2_active
Remote2_OPEN
Remote_2_CLOSE
Remote2_STOP
Execute PVST
Bypass Sync In
PID setpoint I/O
PID act. value I/O
RelOPENandCLOSE
Speed int. sel. bit 0
Speed int. sel. bit 1
Syn. link End pos. In
Syn. link Remote In
Sync. link Ready In
Depending on the version, the actuator controls are equipped with up to 10 digital
inputs.
The inputs are designed for binary signals (standard input level: +24 V DC) and can
be used, for example, to receive operation commands OPEN, STOP, CLOSE, to
control intermediate positions or for the EMERGENCY signal.
Configuration of digital inputs
Required user level: Specialist (4).
Device configuration M0053
I/O interface M0139
Digital inputs M0116
Description
Input not assigned
Change-over between OPEN - CLOSE control and setpoint control
Operation command OPEN
Operation command CLOSE
Operation command STOP
Reset fault signal
Change-over between fieldbus interface and parallel interface
Operation command OPEN/CLOSE for two-wire control
Operation mode for EMERGENCY behaviour
Operation command: Run to intermediate position 1.
Operation command: Run to intermediate position 2.
Operation command: Run to intermediate position 3.
Operation command: Run to intermediate position 4.
Operation command: Run to intermediate position 5.
Operation command: Run to intermediate position 6.
Operation command: Run to intermediate position 7.
Operation command: Run to intermediate position 8.
Signal for controlling output contact
Signal for controlling output contact
Signal for controlling output contact
Signal for controlling output contact
Enables the selector switch function (LOCAL/OFF) on the local controls
Interlock: Enables operation command in direction OPEN
Interlock: Enables operation command in direction CLOSE
Internal PID setpoint
Activation of operation mode Remote II
Operation command OPEN in operation mode Remote II
Operation command CLOSE in operation mode Remote II
Operation command STOP in operation mode Remote II
PVST is executed
Enable signal for <By-pass function>
Change-over of process controller setpoint source between fieldbus interface and I/O interface
Change-over of process controller actual value source between fieldbus interface and I/O interface
Enable signal OPEN/CLOSE
Signal 1 for external speed selection
Signal 2 for external speed selection
Synchronous link, signal of the slave actuator: Actuator is in end position OPEN/CLOSED
Synchronous link, signal of the slave actuator: Selector switch is in position REMOTE
Synchronous link, signal of the slave actuator: Ready for operation