Signal
Running LOCAL
Running REMOTE
Handwheel oper.
In intermediate pos.
Intermediate pos. 1
Intermediate pos. 2
Intermediate pos. 3
Intermediate pos. 4
Intermediate pos. 5
Intermediate pos. 6
Intermediate pos. 7
Intermediate pos. 8
Input DIN 1
Input DIN 2
Input DIN 3
Input DIN 4
Input DIN 5
Input DIN 6
EMCY stop active
Torque fault CLOSE
Torque fault OPEN
Torque fault
Thermal fault
Phase fault
Handwheel active
PVST active
PVST fault
PVST abort
Failure (configurable)
Interlock Remote
Interlock Local
Interlock OPEN
Interlock CLOSE
Interlock
Bypass Sync Out
Interlock by-pass
Safe ESD
Safe Stop
System ok
Torque wrn OPEN
Torque wrn CLOSE
Maintenance reminder
130
Description
Output drive rotates due to operation command from LOCAL.
Output drive rotates due to operation command from REMOTE.
Output drive rotates without electric operation command.
The actuator is in an intermediate position e.g. neither in end position OPEN nor in end position CLOSED.
Intermediate position 1 reached
Intermediate position 2 reached
Intermediate position 3 reached
Intermediate position 4 reached
Intermediate position 5 reached
Intermediate position 6 reached
Intermediate position 7 reached
Intermediate position 8 reached
A high signal (+24 V DC) is present at digital input 1.
A high signal (+24 V DC) is present at digital input 2.
A high signal (+24 V DC) is present at digital input 3.
A high signal (+24 V DC) is present at digital input 4.
A high signal (+24 V DC) is present at digital input 5.
A high signal (+24 V DC) is present at digital input 6.
Operation mode EMERGENCY stop is active (EMERGENCY stop button has been pressed).
Torque fault in direction CLOSE
Torque fault in direction OPEN
Torque fault in directions CLOSE or OPEN
Motor protection tripped
One phase missing
Manual operation is active (handwheel is engaged); optional signal.
Partial Valve Stroke Test (PVST) is active.
Partial Valve Stroke Test (PVST) could not be successfully completed.
Partial Valve Stroke Test (PVST) was aborted or could not be started. Remedy: Perform RESET or restart
PVST.
This signal can be configured (parameter Failure (configurable) M0879) and comprises a combination
of the following signals which can also be configured:
Fault (Cfg) M0880
Warnings (Cfg) M0881
Not ready REMOTE (Cfg) M0882
Function Interlock is active for operation mode REMOTE.
Function Interlock is active for operation mode Local.
Interlock OPEN is active (enable signal for operation commands in direction OPEN available).
Interlock CLOSED is active (enable signal for operation commands in direction CLOSE available).
The operation mode Interlock is active.
<By-pass function> enable for operation commands of main or by-pass valves is active.
Operation command executed without enable signal Bypass Sync Out.
Safe ESD function (Emergency Shut Down) is active.
Safe STOP function is active.
The actuator is switched on and no fault is present
This signal will be activated if at least on the lifetime accounts (in %) has passed the activation threshold
configured for this signal.
This signal can be configured (parameter Maintenance required M0871) and comprises a combination
of the following signals:
Mainten. mechanics
Mainten. lubricant
Mainten. contactors
Mainten. interval