System Block Diagram - SSANGYONG Rodius 2012.07 Manual

Table of Contents

Advertisement

01-8

2. SYSTEM BLOCK DIAGRAM

A/C compressor OFF conditions
Coolant temperature: over 115℃
1.
2.
Engine speed: over 4,500 rpm for more than 2 seconds
3.
Engine speed: below 650 rpm
4.
Maximum output due to abrupt acceleration
5.
Excessive acceleration
6.
Increased load during engine idling (to prevent the engine from shutting off)
7.
Refrigerant pressure: over 32 bar or below 2 bar
8.
Defects in A/C related system (refrigerant pressure sensor, coolant temperature sensor,
cooling fan)