14-11
2412-02
1) Oxidation of DOC
The DOC oxidizes HC and CO of the exhaust gas in the two-way catalytic converter at 180℃ or
more, and performs best at the temperature between 400 and 500℃. The front EGT sensor
detects whether the DOC can burn (oxidize) the post-injected fuel or not, and sends the signal to
the ECU to maintain the DOC operating temperature between 300 and 500℃. The DOC reduces
CO and HC of the exhaust gas by redox reaction and also reduces small amount of PM.
Oxygen adheres to the catalyst materials: Less than 180℃
1.
CO and HC are oxidized by the catalyst materials: More than 180℃
2.

Hide quick links: