Festo MS6-SV-E Operating Instructions Manual page 70

Soft-start/quick exhaust valve
Table of Contents

Advertisement

Available languages

Available languages

MS6-SV-...-E-10V24
Type
Switching point
Filling flow
Nominal operating voltage DC
Permissible voltage fluctuation
Max. switching frequency
Switching time off
Switching time on
Duty cycle
Electrical connection
Protection class
Noise level
Information on material, housing
Information on material, seal
Max. current consumption
Protection against electric shock
(protection against direct and indirect
contact as per EN 60204-1/IEC 204)
Switching position display
Semiconductor relay (signal contact)
– Max. voltage
– Max. continuous current
– Max. resistance in the
switched-on status
– Max. leakage current in the
switched-off status
Min. pause after exhausting
Protection class
Fire protection classification to UL94
1) During the switch on process, an increased starting current takes place short-term.
Tab. 9
General data
70
MS6-SV-E
Approx. 50 % of p1
Adjustable through flow control valve
[V]
24
[%]
±10
[Hz]
0.5
[ms]
40
[ms]
130
[%]
100
Sub-D, 9-pin (the product may only be operated with
the related multi-pin plug sockets NECA-S1G9-P9-MP...)
IP65 with multi-pin plug socket NECA-...
[dB(A)]
75 with silencer UOS-1
Die-cast aluminium
NBR
1)
[A]
0.12
By means of PELV power supply unit
LED and potential-free contact
[V]
60
[A]
0.12
[Ω]
25 (typ. 18)
[μA]
1
[s]
1
III
V0-V2
Fig. 11
Festo – MS6-SV-...-E-10V24 – 1310b English
Fig. 19

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Ms6-sv-...-e-10v24 series

Table of Contents