Festo MS6-SV-E Operating Instructions Manual page 74

Soft-start/quick exhaust valve
Table of Contents

Advertisement

Available languages

Available languages

MS6-SV-...-E-10V24
EN2 before EN1 (for multi-pin plug socket NECA-S1G9-P9-MP1)
EN2:
enable signal 2
EN1:
enable signal 1
Signal contacts
Max. reaction time from pressurisation until exhausting: t2 + t1 = 75 ms + 5 ms = 80 ms
Max. reaction time from pressurisation until exhausting: t3 + t4 = 15 ms + 2 ms = 17 ms
EN1 before EN2 (for multi-pin plug socket NECA-S1G9-P9-MP1)
EN2:
enable signal 2
EN1:
enable signal 1
Signal contacts
Max. reaction time from exhausting until pressurisation: t2 + t1 + t4 = 75 ms + 5 ms + 2 ms = 82 ms
Max. reaction time from pressurisation until exhausting: t2 + t3 + t4 = 75 ms + 15 ms + 2 ms = 92 ms
t1 > 5 ms:
Level of EN2/EN1 must be HIGH for min. 5 ms (debounce time/input filter/stabilisation
time).
t2 <= 75 ms:
Max. permissible delay time between EN1 and EN2. If exceeded, the MS6-SV-E is not
pressurized and an error message is output.
t3 >= 15 ms:
Level of EN2/EN1 must be LOW for min. 15 ms (debounce time/input filter/stabilisation
time).
t4 = 2 ms:
Max. internal time delay caused by the program sequence.
tp
:
Pressurisation 300 ms
1 } 2
tp
:
Exhausting 1 s
2 } 3
Fig. 21
Runtime performance of enable signals with NECA-...-MP1
74
Festo – MS6-SV-...-E-10V24 – 1310b English