MS6-SV-...-E-10V24
14.5.2

Switching characteristics for multi-pin plug socket NECA-S1G9-P9-MP3/-MP5

Operating
pressure p1
Output pressure p2
+L1: operating voltage
EN1: enable signal 1
EN2: enable signal 2
Signal contacts
Power LED (green)
Error LED (red)
Fig. 22
Input and output switching characteristics in normal operation (when the "Automatic start"
operating mode is set) for multi-pin plug socket NECA-S1G9-P9-MP3/-MP5
For NECA-...-MP3, exhausting and output of an error message occurs when:
• EN1 and EN2 = 0 V (LOW)
• EN1 and EN2 = 24 V (HIGH)
For NECA-...-MP5, exhausting and output of no error message occurs when:
• EN1 and EN2 = 0 V (LOW)
• EN1 and EN2 = 24 V (HIGH)
The diagrams on the next page show the precise switching characteristics of the Enable signals EN1
and EN2 with a time offset. The maximum reaction time can be derived from the delay between the two
signals.