Agilent Technologies X Series Programmer's Manual page 97

Signal analyzer
Hide thumbs Also See for X Series:
Table of Contents

Advertisement

7. Tell the MXG to
expect a list of powers.
8. Tell the MXG how
the lists will be entered.
9. Send the MXG a list
of frequencies
10. Send the MXG a list
of powers
11. Turn off signal
modulation.
12. Turn signal output
on.
13. Configure the
MXG's LXI Output
LAN Event
14. Set the MXG's
trigger source.
15. Enable the MXG's
LXI LAN Event trigger
Chapter 3
:POW:MODE LIST
:LIST:TYPE LIST
:LIST:FREQ 100 MHz, 200 MHz, 300
MHz, 400 MHz, 500 MHz
:LIST:POW 0 dBm, -1 dBm, -2 dBm,
-3 dBm, -4 dBm
:OUTP:MOD OFF
:OUTP ON
LXI:EVENt:OUTPut:LAN:DRIVe
"LAN0",NORMal
LXI:EVENt:OUTPut:LAN:SLOPe
"LAN0",POS
LXI:EVENt:OUTPut:LAN:SOURce
"LAN0","WaitingForTrigger"
LIST:TRIG:SOUR LAN
TRIG:LXI:LAN:ENABled "LAN1",1
Measurement Synchronization with LXI-B
Setting Up and Executing a List Sweep Measurement
This command is sent
to the MXG.
An arbitrary list will be
used instead of range
and step size
arguments.
This command is sent
to the MXG.
The MXG will put out
signals at these
frequencies and in this
order.
This command is sent
to the MXG.
The MXG will put out
signals at these powers
and in this order.
This command is sent
to the MXG.
This command is sent
to the MXG.
These commands are
sent to the MXG.
Together, these
commands will cause
the MXG to send a
"LAN0" peer to peer
message every time the
WaitingForTrigger
instrument event
changes state.
This command is sent
to the MXG.
This command is sent
to the MXG.
The MXG will step
through its list when it
receives a "LAN1" peer
to peer message.
97

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Exa n9010aMxa n9020a