Control Unit - MOTO GUZZI V85 TT Service Station Manual

Hide thumbs Also See for V85 TT:
Table of Contents

Advertisement

V85 TT

Control unit

REMOVAL
Remove the saddle
Unscrew and remove the screws (1)
Disconnect the connectors (2)
Remove the ECU (3)
NOTE
WHEN REASSEMBLING THE CONNECTORS, THE SLIDES MUST SLIDE FREELY UP TO THE
LIMIT STOP, THUS FACILITATING THE CONNECTOR'S INSERTION. THE CATCH SHOULD SNAP
INTO PLACE ONCE THE LIMIT STOP IS REACHED.
P160C Level 2 safety reset
Error cause:
Due to the fact that the level 2 safety system (comparison between requested torque and
calculated torque) detected a fault, the control unit reset the engine (severity C).
The instrument panel does not indicate the presence of this error even in the ATT status.
Troubleshooting:
Perform the troubleshooting for the other detected errors
P1650 Engine events configuration Checksum calculation error